A Novel Voltage Sag Detection Method Based on a Selective Harmonic Extraction Algorithm for Nonideal Grid Conditions
Zhenyu Li,
Ranchen Yang,
Xiao Guo,
Ziming Wang and
Guozhu Chen
Additional contact information
Zhenyu Li: Department of Electrical Engineering, Zhejiang University, No. 38 Zheda Road, Xihu District, Hangzhou 310027, China
Ranchen Yang: Department of Electrical Engineering, Zhejiang University, No. 38 Zheda Road, Xihu District, Hangzhou 310027, China
Xiao Guo: Department of Electrical Engineering, Zhejiang University, No. 38 Zheda Road, Xihu District, Hangzhou 310027, China
Ziming Wang: Department of Electrical Engineering, Zhejiang University, No. 38 Zheda Road, Xihu District, Hangzhou 310027, China
Guozhu Chen: Department of Electrical Engineering, Zhejiang University, No. 38 Zheda Road, Xihu District, Hangzhou 310027, China
Energies, 2022, vol. 15, issue 15, 1-21
Abstract:
Voltage sag detection is utilized to capture the sag occurrence moment and calculate the sag depth of power grid voltage in real time, so as to generate reference voltage for controlling voltage interactive equipment such as dynamic voltage restorers (DVRs). However, the traditional voltage sag detection methods based on synchronously rotating frames (SRFs) are unable to acquire high-precision sag information under nonideal grid conditions such as unbalance or harmonic interference. In order to enhance the immunity of the sag detection, a method based on a selective harmonic extraction algorithm (SHEA) is proposed in this paper. Firstly, the state-space model of SHEA is established using discrete orthogonal basis to decouple and separate the signal of target frequency and the signal of interference frequency. The controllability, stability and convergence of SHEA are analyzed theoretically and serve as the criteria for parameter tuning. Moreover, a gain compensator (GC) is used to improve the low and middle frequency gains of the voltage sag detection method based on SHEA so that the dynamic response speed for sag judgment can be optimized quantitatively. The simulation results indicate that the proposed voltage sag detection method has good dynamic and steady-state performance under nonideal power grid conditions such as unbalanced sag, frequency drift, phase variation and harmonic interference.
Keywords: voltage sag detection algorithm; dynamic voltage restorer; nonideal grid conditions; modeling and optimization (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/15/5560/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/15/5560/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:15:p:5560-:d:876864
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().