Air-Side Nusselt Numbers and Friction Factor’s Individual Correlations of Finned Heat Exchangers
Mateusz Marcinkowski,
Dawid Taler,
Jan Taler and
Katarzyna Węglarz
Additional contact information
Mateusz Marcinkowski: Faculty of Environmental Engineering and Energy, Cracow University of Technology, 31-155 Cracow, Poland
Dawid Taler: Faculty of Environmental Engineering and Energy, Cracow University of Technology, 31-155 Cracow, Poland
Jan Taler: Faculty of Environmental Engineering and Energy, Cracow University of Technology, 31-155 Cracow, Poland
Katarzyna Węglarz: Faculty of Environmental Engineering and Energy, Cracow University of Technology, 31-155 Cracow, Poland
Energies, 2022, vol. 15, issue 15, 1-17
Abstract:
Currently, when designing finned heat exchangers (FHE), the average value of the entire heat transfer coefficient (HTC) is considered. However, each row of the heat exchanger (HEX) has different hydraulic-thermal characteristics. The novelty of this research is to present the differentiation of the individual air-side Nusselt number and Darcy-Weisbach friction factor correlations in each row of FHE using CFD modelling. FHE has four-rows, circular tubes, and continuous fins with a staggered tube arrangement. Relationships for the Nusselt number and D-W friction factor derived for the entire exchanger based on CFD modelling were compared with those available in the literature, determined using experimental data. The maximum relative differences between the Nusselt number for a four-row FHE determined experimentally and by CFD modelling are in the range from 22% for a Reynolds number based on a tube outside diameter of 1000 to 30% for a Reynolds number of 13,000. The maximum relative differences between the D-W friction factor for a four-row FHE determined experimentally and by CFD modelling are in the range of 50% for a Reynolds number based on a tube outer diameter of 1000 to 10% for a Reynolds number of 13,000. The CFD modelling performed shows that in the range of Reynolds numbers based on hydraulic diameters from 150 to 1400, the Nusselt number for the first row in a four-row FHE is about 22% to 15% higher than the average Nusselt number for the entire exchanger. In the range of Reynolds number changes based on hydraulic diameter from 2800 to 6000, the Nusselt numbers on the first and second rows of tubes are close to each other. Correlations of Nusselt numbers and D-W friction factors derived for individual tube rows can be used in the design of plate-fin and tube heat exchangers used in equipment such as air-source heat pumps, automotive radiators, air-conditioning systems, and in air hot-liquid coolers. In particular, the correlations can be used to select the optimum number of tube rows in the exchanger.
Keywords: finned heat exchanger; Nusselt number; friction factor; individual correlations; CFD; air heat pump (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/15/5630/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/15/5630/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:15:p:5630-:d:879177
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().