Life Cycle Assessment of Dispersed Phase Change Material Heat Accumulators for Cooperation with Buildings in the District Heating System

Michał Turski () and Agnieszka Jachura
Additional contact information
Michał Turski: Faculty of Infrastructure and Environment, Czestochowa University of Technology, 73 J.H. Dąbrowskiego St., 42-200 Czestochowa, Poland
Agnieszka Jachura: Faculty of Infrastructure and Environment, Czestochowa University of Technology, 73 J.H. Dąbrowskiego St., 42-200 Czestochowa, Poland

Energies, 2022, vol. 15, issue 16, 1-24

Abstract: The wide use of energy-efficient district heating systems allows for decreased atmospheric pollution resulting from lower emissions. One of the ways to increase the efficiency of existing district heating systems, and a key element of new systems using renewable energy sources, is modern heat storage technology—the utilization of dispersed PCM heat accumulators. However, the use of different solutions and the inconsistency of selection methods make it difficult to compare the obtained results. Therefore, in this paper, using TRNSYS software, a standardization of the selection of dispersed PCM heat accumulators for cooperation with buildings in the DHS was proposed along with a Life Cycle Assessment. Life Cycle Assessment could be a good, versatile indicator for new developments in district heating systems. A new contribution to the research topic was the Life Cycle Assessment itself as well as the range of heat output of the substations up to 2000 kW and the development of nomograms and unitary values for the selection of individual parameters based on the relative amount of heat uncollected by buildings. The technical potential of heat storage value, %Δ Q i , st , was from 49.4% to 59.6% of the theoretical potential of heat storage. The increases in the active volume of the PCM heat accumulator, d V PCM , and the mass of the required amount of PCM, d m st , were, respectively, 0.8 × 10 −2 –4.0 m 3 /kW and 1.3–6.7 × 10 −2 kg/kW. Due to dispersed heat storage, an increase in system efficiency of 41% was achieved. LCA analysis showed that a positive impact on the environment was achieved, expressed as negative values of the Eco-indicator from −0.504 × 10 −2 to −6.44 × 10 −2 kPt/kW.

Keywords: district heating system; hybrid substations; PCM; district heating storage; life cycle assessment (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (4)

Downloads: (external link)
https://www.mdpi.com/1996-1073/15/16/5771/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/16/5771/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:16:p:5771-:d:883751

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:15:y:2022:i:16:p:5771-:d:883751