EconPapers    
Economics at your fingertips  
 

Design of an Anti-Corona Device for HVAC Substation Connectors

Ane Miren Larrea, Manuel De La Hoz, Agurtzane Etxegarai, Angel Javier Mazon () and Itxaso Aranzabal
Additional contact information
Ane Miren Larrea: Department of Electrical Engineering, Faculty of Engineering of Bilbao, University of the Basque Country UPV/EHU, 48013 Bilbao, Spain
Manuel De La Hoz: Department of Electrical Engineering, Faculty of Engineering of Bilbao, University of the Basque Country UPV/EHU, 48013 Bilbao, Spain
Agurtzane Etxegarai: Department of Electrical Engineering, Faculty of Engineering of Bilbao, University of the Basque Country UPV/EHU, 48013 Bilbao, Spain
Angel Javier Mazon: Department of Electrical Engineering, Faculty of Engineering of Bilbao, University of the Basque Country UPV/EHU, 48013 Bilbao, Spain
Itxaso Aranzabal: Department of Electrical Engineering, Faculty of Engineering of Bilbao, University of the Basque Country UPV/EHU, 48013 Bilbao, Spain

Energies, 2022, vol. 15, issue 16, 1-12

Abstract: One of the aspects to consider during high-voltage (HV) equipment design is the reduction in the probability of corona effect onset. Indeed, the corona effect is related to high electric field values beyond the equipment’s insulation levels and insulation strength, among other factors. This issue can be addressed during the design step, either by modifying the geometry of the electrical device or by including additional elements in the equipment structure to smooth out the voltage gradient along critical regions, such as anti-corona devices. The study of anti-corona devices for HV insulators is well documented, in contrast to substation connectors. Therefore, the present study proposed the design of a novel anti-corona device for HV substation connectors, including a method for the selection of its dimensions. This study shows that the relationship between the dimensional design variables and the critical electrical field on the connector is described by linear and rational functions. Thus, the design process times are cut down due to a reduction in the number of simulations required to run the assessment of the anti-corona device arrangement impact.

Keywords: computer-aided manufacturing; connector; corona ring; electric fields; high voltage (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/15/16/5781/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/16/5781/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:16:p:5781-:d:884022

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:15:y:2022:i:16:p:5781-:d:884022