Peculiarities of Calculating the Thermal Conductivity of Moist Autoclaved Aerated Concrete
Beata Backiel-Brzozowska (),
Vadzim I. Nikitsin,
Abdrahman Alsabry,
Serafim K. Nikitsin and
Wioleta Rutkowska
Additional contact information
Beata Backiel-Brzozowska: Faculty of Civil Engineering and Environmental Sciences, Institute of Civil Engineering and Transport, Bialystok University of Technology, 45 Wiejska Str., 15-351 Bialystok, Poland
Vadzim I. Nikitsin: Faculty of Mechanical Engineering, Brest State Technical University, 267 Moskovskaya Str., 224017 Brest, Belarus
Abdrahman Alsabry: Faculty of Civil Engineering, Architecture and Environmental Engineering, Institute of Civil Engineering, University of Zielona Gora, 1 Prof. Z. Szafrana Str., 65-516 Zielona Gora, Poland
Serafim K. Nikitsin: Faculty of Electronic Information Systems, Brest State Technical University, 267 Moskovskaya Str., 224017 Brest, Belarus
Wioleta Rutkowska: Faculty of Civil Engineering and Environmental Sciences, Institute of Civil Engineering and Transport, Bialystok University of Technology, 45 Wiejska Str., 15-351 Bialystok, Poland
Energies, 2022, vol. 15, issue 16, 1-11
Abstract:
The pore space of autoclaved aerated concretes (ACCs), regardless of their apparent density, is represented by large pores formed as a result of gas formation and fine capillary pores. With the free absorption of liquid moisture, only the capillary pores are filled. Large pores contain vapor-air mixture. Considering such a bimodal pore size distribution, it is proposed to determine the thermal conductivity of moist ACC in two stages. First, an inhomogeneous ternary system that consists of a solid skeleton with a fine porous structure containing gas and liquid moisture should be considered. Then a binary system is taken into account, the first component of which is the mentioned ternary system, and the other component of which consists of isolated gas inclusions in large pores. To determine the thermal conductivity of the ternary system, the dependences constructed using the theory of generalized conductivity were used. The thermal conductivity of the binary system was calculated using well-known formulas. It was found that the results of thermal conductivity calculations based on the proposed two-step method deviate from the experimental data in the range from −7.29 to +5.75%, with an average deviation of −0.71%. With the one-step calculation method (assuming a unimodal pore distribution), the spread of analogous data ranges from −30.72 to −21.98%, with an average deviation of −26%.
Keywords: effective thermal conductivity; autoclave aerated concrete; bimodal pore size distribution; modeling of the structure of moist material; theory of generalized conductivity (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/16/5831/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/16/5831/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:16:p:5831-:d:885974
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().