EconPapers    
Economics at your fingertips  
 

A Method for Estimating On-Field Photovoltaics System Efficiency Using Thermal Imaging and Weather Instrument Data and an Unmanned Aerial Vehicle

Wei-Hsiang Chiang, Han-Sheng Wu, Jong-Shinn Wu () and Shiow-Jyu Lin ()
Additional contact information
Wei-Hsiang Chiang: College of Photonics, National Yang Ming Chiao Tung University, Tainan 71150, Taiwan
Han-Sheng Wu: College of Photonics, National Yang Ming Chiao Tung University, Tainan 71150, Taiwan
Jong-Shinn Wu: Department of Mechanical Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan
Shiow-Jyu Lin: Department of Electronic Engineering, National Ilan University, Ilan 260007, Taiwan

Energies, 2022, vol. 15, issue 16, 1-12

Abstract: A new approach is proposed for estimating the power efficiency of an on-field solar photovoltaics (PV) system using data from thermal imaging and weather instruments obtained using an unmanned aerial vehicle (UAV). This method is specifically designed for the non-intrusive detection of the performance of the PV system in a large-scale solar power plant that could be efficient, manpower saving, operationally safe and comprehensive. In this study, a drone instrumented with a radiometer, a thermometer and an anemometer flew at a height of 1.5 m with a maximum lateral flight speed of 3.6 m/s above the PV modules (60 cells each) with hotspots or with aging but without hotspots. The average temperatures of the PV modules were then calculated through the measured radiation intensity, ambient temperature and wind speed based on the published correlation formula. The experimental correlations were obtained by measuring over 60 aging PV modules without hot-spot damage, and the uncertainties of the estimated efficiencies fell between 2% and 5%. Through the use of 20 hot-spot damaged PV modules when the measured temperatures of the cells were in the range of 80–90 °C, it was found that based on the experimental correlationd, their power efficiencies would be lower than 40% if more than eight cells had hot spots in a PV module. By taking this simple measure, the operator can decide which PV module is damaged and should be replaced immediately. By taking such measures, one can reduce the loading effect of solar PV modules adjacent to them because of the low efficiency and high impedance caused by the damage. We believe the new approach developed in this study could be very cost-effective and time-saving for improving the efficiency of power plant operations.

Keywords: IR-imaging; outdoor testing; UAV detection; hotspots; cell efficiency (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/15/16/5835/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/16/5835/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:16:p:5835-:d:885845

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:15:y:2022:i:16:p:5835-:d:885845