An Offline and Online Approach to the OLTC Condition Monitoring: A Review

Firas B. Ismail (), Maisarah Mazwan, Hussein Al-Faiz, Marayati Marsadek, Hasril Hasini, Ammar Al-Bazi and Young Zaidey Yang Ghazali
Additional contact information
Firas B. Ismail: Power Generation Unit, Institute of Power Engineering (IPE), Universiti Tenaga Nasional, Kajang 43000, Malaysia
Maisarah Mazwan: Power Generation Unit, Institute of Power Engineering (IPE), Universiti Tenaga Nasional, Kajang 43000, Malaysia
Hussein Al-Faiz: Power Generation Unit, Institute of Power Engineering (IPE), Universiti Tenaga Nasional, Kajang 43000, Malaysia
Marayati Marsadek: Power Generation Unit, Institute of Power Engineering (IPE), Universiti Tenaga Nasional, Kajang 43000, Malaysia
Hasril Hasini: Power Generation Unit, Institute of Power Engineering (IPE), Universiti Tenaga Nasional, Kajang 43000, Malaysia
Ammar Al-Bazi: School of Mechanical, Aerospace and Automotive Engineering, Coventry University, Coventry CV1 5FB, UK
Young Zaidey Yang Ghazali: Asset Management Department, Tenaga Nasional Berhad, Kuala Lumpur 59200, Malaysia

Energies, 2022, vol. 15, issue 17, 1-18

Abstract: Transformer failures have a significant cost impact on the operation of an electrical network. In many utilities, transformers have been operating for many years past their expected usable life. As power demand has surged, transformers in some areas are being loaded beyond their rated capacity to meet the demand. One of the vital components in a transformer is the on-load tap changer (OLTC), which regulates the voltage in the distribution network. This study aims to review several condition-monitoring techniques (online and offline) that can monitor the health of the OLTC and assure the safety of the transformer’s OLTC from irreparable damage by detecting the defect at an earlier stage, which is preceded by the specification of typical faults. This paper also discussed the common faults of the OLTC and the root causes of these faults. The OLTC is prone to mechanical faults due to its frequently changing mechanism in the tap operation. The OLTC are also prone to oil as well as thermal faults. As a result, it is critical to monitor OLTC conditions while they are in use. Proper management of condition monitoring (CM) for the OLTC is useful and necessary to increase availability and achieve optimised operating. Condition monitoring (CM) and diagnostics methods (DM) have been developing since the 1950s. CM and DM have been implemented to diagnose and detect an incipient fault, especially for the OLTC. Many techniques, online and offline, are being used to monitor the condition of the OLTC to prevent failure and minimize outages. These DM and CM will prolong the operational cycle and avoid a major disaster for the OLTC, which is an unfavorable scenario.

Keywords: on-load tap changer (OLTC); condition monitoring; diagnostic methods; incipient fault; transformer; energy; electricity distribution (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1996-1073/15/17/6435/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/17/6435/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:17:p:6435-:d:905683

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:15:y:2022:i:17:p:6435-:d:905683