Operation Method of On-Load Tap Changer on Main Transformer Considering Reverse Power Flow in Distribution System Connected with High Penetration on Photovoltaic System
Kwang-Hoon Yoon,
Joong-Woo Shin,
Tea-Yang Nam,
Jae-Chul Kim and
Won-Sik Moon ()
Additional contact information
Kwang-Hoon Yoon: Department of Electrical Engineering, Soongsil University, 369 Sangdo-ro, Dongjak-gu, Seoul 06978, Korea
Joong-Woo Shin: Department of Electrical Engineering, Soongsil University, 369 Sangdo-ro, Dongjak-gu, Seoul 06978, Korea
Tea-Yang Nam: Department of Electrical Engineering, Soongsil University, 369 Sangdo-ro, Dongjak-gu, Seoul 06978, Korea
Jae-Chul Kim: Department of Electrical Engineering, Soongsil University, 369 Sangdo-ro, Dongjak-gu, Seoul 06978, Korea
Won-Sik Moon: Department of Electrical Engineering, Soongsil University, 369 Sangdo-ro, Dongjak-gu, Seoul 06978, Korea
Energies, 2022, vol. 15, issue 17, 1-17
Abstract:
The increasing use of photovoltaics (PVs) in distribution systems owing to the low-carbon policy has given rise to the need for various technological changes. In particular, the operation of on-load tap changers (OLTCs) has attracted attention. In traditional distribution systems, the OLTC operates via a line-drop compensator (LDC), which focuses on the load to solve the low-voltage problem; however, the problem of over-voltage caused by PVs persists. Currently, a method for operating an OLTC using the measured voltage is being researched; however, solving the voltage problem for several feeders connected to a main transformer (MT) is not viable. Therefore, this study proposes an OLTC operation method to address the feeder with the largest voltage problem depending on the direction of power flow. The proposed method selects a point where the OLTC operates using the difference between the measured and reference voltages. Setting the reference voltage can solve the problem that occurs due to the direction of power flow. Finally, the effectiveness of the proposed method is verified via case studies. Based on the results, we can conclude that the proposed method effectively solves the voltage problem, and an increase in hosting capacity can be expected.
Keywords: reverse power flow; on-load tap changer; photovoltaic generation; distribution system (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/17/6473/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/17/6473/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:17:p:6473-:d:906862
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().