Experimental Investigation and Performance Characteristics of Francis Turbine with Different Guide Vane Openings in Hydro Distributed Generation Power Plants
Megavath Vijay Kumar (),
T. Subba Reddy,
P. Sarala,
P. Srinivasa Varma,
Obbu Chandra Sekhar,
Abdulrahman Babqi,
Yasser Alharbi,
Basem Alamri () and
Ch. Rami Reddy
Additional contact information
Megavath Vijay Kumar: Department of Mechanical Engineering, Malla Reddy Engineering College, Maisammaguda, Secunderabad 500100, India
T. Subba Reddy: Department of Mechanical Engineering, Andhra Loyola Institute of Engineering and Technology, Vijayawada 520008, India
P. Sarala: Department of Electrical and Electronics Engineering, Malla Reddy Engineering College, Secunderabad 500100, India
P. Srinivasa Varma: Department of Electrical and Electronics Engineering, Koneru Lakshmaiah Education Foundation, Vaddeswaram 522502, India
Obbu Chandra Sekhar: Department of Electrical Engineering, National Institute of Technology, Srinagar 190006, India
Abdulrahman Babqi: Department of Electrical Engineering, College of Engineering, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia
Yasser Alharbi: Department of Electrical Engineering, College of Engineering, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia
Basem Alamri: Department of Electrical Engineering, College of Engineering, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia
Ch. Rami Reddy: Department of Electrical and Electronics Engineering, Malla Reddy Engineering College, Secunderabad 500100, India
Energies, 2022, vol. 15, issue 18, 1-24
Abstract:
This article presents a study on the performance characteristics of a Francis turbine operating with various guide vane openings to determine the best operating point based on unit quantities. The guide vane openings were specified based on the width between the vanes at their exit, i.e., 10 mm, 13 mm, 16 mm, and 19 mm. The performance characteristic curves of the Francis turbine—head versus speed, torque versus speed, discharge versus speed, and efficiency versus speed—were obtained at various input power and guide vane openings. From these data, unit curves were plotted and the corresponding best efficiency points were obtained. The highest efficiency of 50.25% was obtained at a guide vane opening of 19 mm. The values of head, discharge, speed, and output power at BEP were 7.84 m, 13.55 lps, 1250 rpm, and 524 W, respectively.
Keywords: renewable energy; Francis turbine; guide vane opening; performances & unit quantities (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/18/6798/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/18/6798/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:18:p:6798-:d:917408
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().