EconPapers    
Economics at your fingertips  
 

Research on the Influence of Moisture Exchange between Oil and Cellulose on the Electrical Parameters of the Insulating Oil in Power Transformers

Konrad Kierczynski (), Przemyslaw Rogalski, Vitalii Bondariev, Pawel Okal and Daniel Korenciak
Additional contact information
Konrad Kierczynski: Department of Electrical Devices and High Voltage Technology, Faculty of Electrical Engineering and Computer Science, Lublin University of Technology, 38A, Nadbystrzycka Str., 20-618 Lublin, Poland
Przemyslaw Rogalski: Department of Electrical Devices and High Voltage Technology, Faculty of Electrical Engineering and Computer Science, Lublin University of Technology, 38A, Nadbystrzycka Str., 20-618 Lublin, Poland
Vitalii Bondariev: Department of Electrical Devices and High Voltage Technology, Faculty of Electrical Engineering and Computer Science, Lublin University of Technology, 38A, Nadbystrzycka Str., 20-618 Lublin, Poland
Pawel Okal: Department of Electrical Devices and High Voltage Technology, Faculty of Electrical Engineering and Computer Science, Lublin University of Technology, 38A, Nadbystrzycka Str., 20-618 Lublin, Poland
Daniel Korenciak: Department of Measurement and Application Electrical Engineering, University of Zilina, 8215/1 Univerzitná, 01026 Zilina, Slovakia

Energies, 2022, vol. 15, issue 20, 1-15

Abstract: The article presents an oil moistening method, identical to the oil moistening in power transformers. Moistening took place through the migration of moisture from the moistened pressboard to the brand new oil. The AC electrical parameters (admittance, phase shift angle, permittivity, loss tangent and conductivity) of the brand new and moistened insulating oil were tested. All measured parameters were found to be affected by the oil moistening. The greatest changes were observed in the loss tangent and conductivity. Moisturization increases the value of tanδ at a frequency of 10 −4 Hz from about 20 to about 70. With an increase in frequency to about 400–1000 Hz, a minimum is observed, the position of which depends on the temperature. Its value for moistened oil is about six times lower than for brand new oil. This moisturizing increased the activation energy of the conductivity from 0.466 ± 0.0265 eV to 0.890 ± 0.0115 eV. This is likely due to the acceleration of water molecules diffusion from the pressboard into the oil with increasing temperatures. The observed changes in the oil parameters caused by moistening should be taken into account while analyzing the power transformers insulation condition using the FDS method.

Keywords: transformer diagnostics; FDS method; insulation of transformers; moisture; mineral oil; cellulose; pressboard (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1996-1073/15/20/7681/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/20/7681/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:20:p:7681-:d:945749

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19