EconPapers    
Economics at your fingertips  
 

Empirical Wavelet Transform-Based Intelligent Protection Scheme for Microgrids

Syed Basit Ali Bukhari (), Abdul Wadood, Tahir Khurshaid, Khawaja Khalid Mehmood, Sang Bong Rhee () and Ki-Chai Kim ()
Additional contact information
Syed Basit Ali Bukhari: Department of Electrical Engineering, The University of Azad Jammu and Kashmir, Muzaffarabad 13100, Pakistan
Abdul Wadood: Department of Electrical Engineering, Air University Islamabad, Aerospace and Aviation Campus, Kamra 43570, Pakistan
Tahir Khurshaid: Department of Electrical Engineering, Yeungnam University, 280 Daehak-ro, Gyeongsan 38541, Korea
Khawaja Khalid Mehmood: Department of Electrical Engineering, The University of Azad Jammu and Kashmir, Muzaffarabad 13100, Pakistan
Sang Bong Rhee: Department of Electrical Engineering, Yeungnam University, 280 Daehak-ro, Gyeongsan 38541, Korea
Ki-Chai Kim: Department of Electrical Engineering, Yeungnam University, 280 Daehak-ro, Gyeongsan 38541, Korea

Energies, 2022, vol. 15, issue 21, 1-17

Abstract: Recently, the concept of the microgrid (MG) has been developed to assist the penetration of large numbers of distributed energy resources (DERs) into distribution networks. However, the integration of DERs in the form of MGs disturbs the operating codes of traditional distribution networks. Consequently, traditional protection strategies cannot be applied to MG against short-circuit faults. This paper presents a novel intelligent protection strategy (NIPS) for MGs based on empirical wavelet transform (EWT) and long short-term memory (LSTM) networks. In the proposed NIPS, firstly, the three-phase current signals measured by protective relays are decomposed into empirical modes (EMs). Then, various statistical features are extracted from the obtained EMs. Afterwards, the extracted features along with the three-phase current measurement are input to three different LSTM network to obtain exact fault type, phase, and location information. Finally, a trip signal based on the obtained fault information is generated to disconnect the faulty portion from the rest of the MG. The significant feature of the proposed NIPS is that it does not need adaptive relaying and communication networks. Moreover, it is independent of the operating scenario and hence fault current magnitude. To evaluate the efficacy of the proposed NIPS, exhaustive simulations are performed on an international electro-technical commission (IEC) MG. The simulation results confirm the efficiency of the proposed NIPs in terms of accuracy, dependability, and security. Moreover, comparisons with existing intelligent protection schemes validate that the proposed NIPS is highly accurate, secure, and dependable.

Keywords: empirical wavelet transform; fault detection; fault classification; long short-term memory network; microgrid protection (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1996-1073/15/21/7995/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/21/7995/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:21:p:7995-:d:955446

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:15:y:2022:i:21:p:7995-:d:955446