Power Quality Assessment in a Real Microgrid-Statistical Assessment of Different Long-Term Working Conditions
Anna Ostrowska,
Łukasz Michalec (),
Marek Skarupski,
Michał Jasiński (),
Tomasz Sikorski,
Paweł Kostyła,
Robert Lis,
Grzegorz Mudrak and
Tomasz Rodziewicz
Additional contact information
Anna Ostrowska: Faculty of Electrical Engineering, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
Łukasz Michalec: Faculty of Electrical Engineering, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
Marek Skarupski: Faculty of Pure and Applied Mathematics, Wrocław University of Science and Technology, 50-370 Wrocław, Poland
Michał Jasiński: Faculty of Electrical Engineering, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
Tomasz Sikorski: Faculty of Electrical Engineering, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
Paweł Kostyła: Faculty of Electrical Engineering, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
Robert Lis: Faculty of Electrical Engineering, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
Grzegorz Mudrak: TAURON Dystrybucja S.A., 31-060 Kraków, Poland
Tomasz Rodziewicz: TAURON Dystrybucja S.A., 31-060 Kraków, Poland
Energies, 2022, vol. 15, issue 21, 1-26
Abstract:
Power quality (PQ) becomes a more and more pressing issue for the operation stability of power systems with renewable energy sources. An important aspect of PQ monitoring of distribution networks is to compare the PQ indicators in different operating conditions. This paper evaluates the impact of a microgrid implementation in a real distribution network on power quality indicators at the point of common coupling in an LV network. The study includes a classical assessment of the long-term PQ parameters according to the EN 50160 standard, such as nominal frequency deviations, voltage RMS variations, voltage fluctuations (represented by long-term flicker severity), voltage unbalance and total harmonic distortion. The PQ evaluation is extended in statistical assessment based on cluster analysis. The case study contains 5 weeks of power quality observation results obtained at the assessment point in two different working conditions of the distribution system: before and after implementing the microgrid. The study allows establishing general conclusions regarding a microgrid interconnection in order not to exceed power quality limits and considering the influence of photovoltaic generation on power quality parameters.
Keywords: distributed generation; energy storage island mode; microgrid; power quality; renewable energy resources; long-term assessment (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/21/8089/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/21/8089/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:21:p:8089-:d:958889
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().