Influence of Fluid Viscosity on Cavitation Characteristics of a Helico-Axial Multiphase Pump (HAMP)
Kaijie Ye,
Denghui He (),
Lin Zhao and
Pengcheng Guo
Additional contact information
Kaijie Ye: Institute of Water Resources and Hydro-Electric Engineering, Xi’an University of Technology, No. 5 Jinhua South Road, Xi’an 710048, China
Denghui He: Institute of Water Resources and Hydro-Electric Engineering, Xi’an University of Technology, No. 5 Jinhua South Road, Xi’an 710048, China
Lin Zhao: Institute of Water Resources and Hydro-Electric Engineering, Xi’an University of Technology, No. 5 Jinhua South Road, Xi’an 710048, China
Pengcheng Guo: Institute of Water Resources and Hydro-Electric Engineering, Xi’an University of Technology, No. 5 Jinhua South Road, Xi’an 710048, China
Energies, 2022, vol. 15, issue 21, 1-14
Abstract:
Fluid viscosity is one of the key factors affecting the cavitation characteristics of the Helico-axial Multiphase Pump (HAMP). In this paper, fluids with viscosities of 24.46 mm 2 /s, 48.48 mm 2 /s, 60.70 mm 2 /s, and 120.0 mm 2 /s were investigated by numerical simulation. The Ansys Fluent software was employed to conduct the simulation. The mixture multiphase flow model and the RNG k-ε turbulence model were adopted. The Singhal cavitation model was employed to consider the effects of the non-condensable gas on cavitation. An experiment was carried out to validate the numerical method. The results showed that the Net Positive Suction Head-available (NPSHA) of the pump decreased as the fluid viscosity increased. Under the critical NPSHA condition, the NPSHA decreased from 5.11 m to 3.68 m as the fluid viscosity increased from 24.46 mm 2 /s to 120.0 mm 2 /s. This suggested that the cavitation performance of the pump was deteriorated under high fluid viscosity. The impeller passage area occupied by the vapor increased when the fluid viscosity increased. Nearly half of the flow passages were occupied by cavitation bubbles when the fluid viscosity increased to 120.0 mm 2 /s. The vapor volume fraction, both on the suction surface and pressure surface of the blade, increased with the fluid viscosity. The vapor on the suction surface was mainly distributed in the region with the streamwise between 0 and 0.36 when the fluid viscosity was 24.46 mm 2 /s; while the high vapor volume fraction range increased to the streamwise of 0.42 when the fluid viscosity increased to 120.0 mm 2 /s. The higher vapor volume fraction corresponded with the lower pressure. It was also found that the turbulent kinetic energy, both on the suction surface and pressure surface, increased with the fluid viscosity, which was the favorite for producing more cavitation bubbles. Furthermore, the maximum velocity area was mainly concentrated in the inlet area of the impeller. The velocity distribution in the impeller was basically the same with the viscosity of 24.46 mm 2 /s and 48.48 mm 2 /s. When the viscosity further increased to 60.70 mm 2 /s, the maximum velocity area in the impeller was relatively large. This study provides a reference for designing the HAMP.
Keywords: numerical simulation; Helico-axial multiphase pump; fluid viscosity; cavitation; Net Positive Suction Head (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/21/8149/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/21/8149/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:21:p:8149-:d:959863
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().