EconPapers    
Economics at your fingertips  
 

Full-Scale Digesters: Model Predictive Control with Online Kinetic Parameter Identification Strategy

Luis G. Cortés (), J. Barbancho, D. F. Larios, J. D. Marin-Batista, A. F. Mohedano, C. Portilla and M. A. de la Rubia
Additional contact information
Luis G. Cortés: Departamento de Tecnología Electrónica, Escuela Politécnica, Universidad de Sevilla, 41011 Seville, Spain
J. Barbancho: Departamento de Tecnología Electrónica, Escuela Politécnica, Universidad de Sevilla, 41011 Seville, Spain
D. F. Larios: Departamento de Tecnología Electrónica, Escuela Politécnica, Universidad de Sevilla, 41011 Seville, Spain
J. D. Marin-Batista: Efuels Technologies Ltd., 42-44 Bishopgate, London EC2N 4AH, UK
A. F. Mohedano: Departamento de Ingeniería Química, Campus de Cantoblanco, Universidad Autonoma de Madrid, 28049 Madrid, Spain
C. Portilla: Facultad de Minas, Universidad Nacional de Colombia, Robledo, Medellín 050034, Colombia
M. A. de la Rubia: Departamento de Ingeniería Química, Campus de Cantoblanco, Universidad Autonoma de Madrid, 28049 Madrid, Spain

Energies, 2022, vol. 15, issue 22, 1-23

Abstract: This work presents a nonlinear model predictive control scheme with a novel structure of observers aiming to create a methodology that allows feasible implementations in industrial anaerobic reactors. In this way, a new step-by-step procedure scheme has been proposed and tested by solving two specific drawbacks reported in the literature responsible for the inefficiencies of those systems in real environments. Firstly, the implementation of control structures based on modeling depends on microorganisms’ concentration measurements; the technology that achieves this is not cost-effective nor viable. Secondly, the reaction rates cannot be considered static because, in the extended anaerobic digestion model (EAM2), the large fluctuation of parameters is unavoidable. To face these two drawbacks, the concentration of acidogens and methanogens, and the values of the two reaction rates considered have been estimated by a structure of two observers using data collected by sensors. After 90 days of operation, the error in convergence was lower than 5% for both observers. Four model predictive controller (MPC) configurations are used to test all the previous information trying to maximize the volume of methane and demonstrate a satisfactory operation in a wide range of scenarios. The results demonstrate an increase in efficiency, ranging from 17.4% to 24.4%, using as a reference an open loop configuration. Finally, the operational robustness of the MPC is compared with simulations performed by traditional alternatives used in industry, the proportional-integral-derivative (PID) controllers, where some simple operational scenarios to manage for an MPC are longer sufficient to disrupt a normal operation in a PID controller. For this controller, the simulation shows an error close to the 100% of the reference value.

Keywords: anaerobic digestion; asymptotic observer; homogeneous reaction systems; kinetic parameter observer; model predictive control; step-ahead (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/15/22/8594/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/22/8594/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:22:p:8594-:d:974947

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:15:y:2022:i:22:p:8594-:d:974947