Recurrent Wavelet Fuzzy Neural Network-Based Reference Compensation Current Control Strategy for Shunt Active Power Filter
Cheng-I Chen (),
Yeong-Chin Chen and
Chung-Hsien Chen
Additional contact information
Cheng-I Chen: Department of Electrical Engineering, National Central University, Taoyuan 32001, Taiwan
Yeong-Chin Chen: Department of Computer Science and Information Engineering, Asia University, Taichung 41354, Taiwan
Chung-Hsien Chen: Metal Industries Research and Development Centre, Taichung 40768, Taiwan
Energies, 2022, vol. 15, issue 22, 1-23
Abstract:
The usage of a shunt active power filter (SAPF) is one of the helpful means to mitigate the reactive power and harmonic current of a power grid. The compensation performance of the SAPF is related to the accuracy of the reference voltage extraction from the utility grid, the control stability of the DC-link voltage regulation, and the synchronization between the source voltage and the reference compensation current. To modify the performance of the SAPF for the harmonic compensation, the control strategy of the SAPF reference compensation current based on the recurrent wavelet fuzzy neural network (RWFNN) is proposed in this paper. There are three sections in the proposed control strategy, including the regulated fundamental positive-sequence extraction (section A), DC-link voltage regulation (section B), and calculation of reference compensation current (section C). By regulating the analysis mechanism with the variation of fundamental frequency in the section A, the accurate reference voltage would be obtained. The control stability for the regulation of the DC-link voltage can be accomplished by applying the RWFNN-based controller in the section B. With the synchronized reference voltage in the section A and the estimated control current in the section B, the reference compensation current can be correctly obtained in the section C. From the case studies with the real-time simulator produced by OPAL-RT Technologies Inc., the effectiveness of proposed control strategy for the SAPF reference compensation current can be verified.
Keywords: shunt active power filter; RWFNN; total harmonic distortion; DC-link voltage regulation; regulated fundamental positive-sequence extraction (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/22/8687/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/22/8687/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:22:p:8687-:d:977648
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().