Doweled cross Laminated Timber (DCLT) Building Air Tightness and Energy Efficiency Measurements: Case Study in Poland
Jadwiga Świrska-Perkowska,
Anna Wicher,
Sławomir Pochwała,
Stanisław Anweiler () and
Michał Böhm
Additional contact information
Jadwiga Świrska-Perkowska: Department of Physics of Materials, Faculty of Civil Engineering and Architecture, Opole University of Technology, Katowicka 48, 45-061 Opole, Poland
Anna Wicher: Department of Physics of Materials, Faculty of Civil Engineering and Architecture, Opole University of Technology, Katowicka 48, 45-061 Opole, Poland
Sławomir Pochwała: Department of Thermal Engineering and Industrial Facilities, Faculty of Mechanical Engineering, Opole University of Technology, Mikołajczyka 5, 45-271 Opole, Poland
Stanisław Anweiler: Department of Process and Environmental Engineering, Faculty of Mechanical Engineering, Opole University of Technology, Mikołajczyka 5, 45-271 Opole, Poland
Michał Böhm: Department of Mechanics and Machine Design, Faculty of Mechanical Engineering, Opole University of Technology, Ulica Mikołajczyka 5, 45-271 Opole, Poland
Energies, 2022, vol. 15, issue 23, 1-23
Abstract:
A contemporary challenge for the construction industry is to develop a technology based on natural building materials which at the same time provides high energy efficiency. This paper presents the results of an airtightness test and a thermal imaging study of a detached house built with technology using cross laminated dowelled timber panels. The thermal conductivity coefficients of the wood wool used to insulate the walls and ceiling of the building have also been measured, the linear heat transfer coefficients of the structural nodes have been numerically determined, and calculations have been made regarding the energy efficiency of the building. On the basis of the research, it was found that the air exchange rate in the analyzed building n 50 is at the level of 4.77 h −1 . Air leaks were also observed in the places of connection of longitudinal walls with the roof and at the junction of window frames with external walls. The experimentally determined thermal conductivity coefficient of the wood wool was ~10% higher than that declared by the manufacturer. Calculations for the energy performance certificate showed that an increase of ~10% in the thermal conductivity coefficient of the wood wool used to insulate the building results in a heating demand increase of 2.1%. It was also found that changing the value of the parameter n 50 from 1.0 h −1 to 4.77 h −1 leads to a 40.1% increase in heat demand for heating the building. At the same time, the indicators for final energy demand EK and non-renewable primary energy demand EP increase by 18.1%.
Keywords: wood; dowelled cross-laminated timber; air tightness; blower door test; energy efficiency (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/23/9029/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/23/9029/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:23:p:9029-:d:987828
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().