Time-Average Heat Transfer Coefficient for Steam-Air Condensation during the Dropping of Containment Pressure
Shaodan Li,
Kai Hui,
Zhiwu Ke () and
Yong Li
Additional contact information
Shaodan Li: Science and Technology on Thermal Energy and Power Laboratory, Wuhan 2nd Ship Design and Research Institute, Wuhan 430205, China
Kai Hui: State Key Laboratory of Multiphase Flow in Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China
Zhiwu Ke: Science and Technology on Thermal Energy and Power Laboratory, Wuhan 2nd Ship Design and Research Institute, Wuhan 430205, China
Yong Li: Science and Technology on Thermal Energy and Power Laboratory, Wuhan 2nd Ship Design and Research Institute, Wuhan 430205, China
Energies, 2022, vol. 15, issue 23, 1-12
Abstract:
The passive containment cooling system (PCCS) has been applied in the new generation nuclear power plant. Previous studies mainly focused on steady-state heat transfer, but the actual heat transfer of PCCS is the transient process. Thus, investigating the transient heat transfer during the containment pressure dropping is necessary. The present study proposes a time-average condensation heat transfer coefficient (time-average condensation HTC) to characterize the intensity of transient condensation heat transfer. The time-average condensation HTC is defined as the heat absorbed per unit heat transfer area and per unit wall subcooling in a unit time. Experiments were performed to research the effect of initial gas-mixture pressure and air mass fraction on transient HTC. The result showed that the more significant gas-mixture pressure and lower air mass fraction could promote the transient-state heat transfer, especially the low air mass fraction. Based on the experimental result, a detailed empirical correlation for the time-average heat transfer coefficient is developed with an error of ±20%. Another simplified empirical correlation that only includes air mass fraction is also proposed to predict the transient heat transfer roughly. Besides, research on self-sustaining stability is also conducted to evaluate the stable operation characteristic of PCCS. The system can respond quickly and then run to a new steady state after interference during the long-term operation of PCCS. The phenomenon above implies that PCCS has good self-sustaining stability.
Keywords: passive containment cooling system; transient-state heat transfer; time-average condensation heat transfer coefficient; self-sustaining stability (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/23/9034/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/23/9034/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:23:p:9034-:d:988015
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().