Analysis of the Effects of Grid-Connected Charging/Discharging Stations on Relay Protection
Qingjie Wang,
Jing Ma (),
Lei Shang and
Shuangyin Chen
Additional contact information
Qingjie Wang: School of Electrical and Electronic Engineering, North China Electric Power University, Beijing 102206, China
Jing Ma: School of Electrical and Electronic Engineering, North China Electric Power University, Beijing 102206, China
Lei Shang: School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
Shuangyin Chen: Institute of New Energy, Wuhan 430202, China
Energies, 2022, vol. 15, issue 23, 1-17
Abstract:
The grid-connected operation of charging/discharging stations changes the original load, power supply, and network structures of the distribution network. It also affects the power flow level and direction and leads to a reduction in the sensitivity and reliability of the relay protection system. The grid connections may even lead to improper operation or failure of the relay protection protocols. In order to solve the above problems, this paper proposes a method that constructs the protection criteria by using the characteristics of the positive sequence comprehensive impedance after internal and external faults. Specifically, based on the difference in amplitude of the differential positive sequence impedance in the feeder after the charging/discharging station is connected to the grid, positive sequence comprehensive impedance is proposed for the purpose of establishing longitudinal differential protection. The results show that the vertical protection principle based on the positive sequence comprehensive impedance has a certain versatility for the protection of distribution networks with charging/discharging stations. Additionally, the protection principle has high sensitivity and is generally unaffected by transition resistance. The applicability of the proposed positive sequence comprehensive impedance vertical protection principle is verified by simulation.
Keywords: charging/discharging station; connected to the grid; fault; positive sequence impedance; relay protection (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/23/9065/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/23/9065/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:23:p:9065-:d:988849
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().