Study on the Performance of a Newly Designed Cooling System Utilizing Dam Water for Internet Data Centers
Selorm Kwaku Anka,
Nicholas Lamptey Boafo,
Kwesi Mensah,
Samuel Boahen,
Kwang Ho Lee and
Jong Min Choi ()
Additional contact information
Selorm Kwaku Anka: Graduate School of Department of Mechanical Engineering, Hanbat National University, Daejeon 34158, Republic of Korea
Nicholas Lamptey Boafo: Graduate School of Department of Mechanical Engineering, Hanbat National University, Daejeon 34158, Republic of Korea
Kwesi Mensah: Lucky Core Insulating Materials Manufacturing, LLC, Dubai, United Arab Emirates
Samuel Boahen: Department of Mechanical Engineering, Kwame Nkrumah University of Science and Technology, PMB, Kumasi AK-039-5028, Ghana
Kwang Ho Lee: Department of Architecture, Korea University, Seoul 02841, Republic of Korea
Jong Min Choi: Department of Mechanical Engineering, Hanbat National University, Daejeon 34158, Republic of Korea
Energies, 2022, vol. 15, issue 24, 1-19
Abstract:
A novel energy-saving hybrid cooling system that combines a forced-cooling cycle and a free-cooling cycle was developed to increase the energy efficiency of cooling systems in year-round operation of an internet data center with high heat loads. This system effectively utilizes a dam deep water source to reduce energy consumption in internet data centers. The hybrid cooling system operates in forced-cooling mode when the entering water temperature exceeds the mode change temperature of 9 °C, but switches to free-cooling mode when the ambient temperature falls below the mode change temperature. In this paper, the cooling performance of the hybrid system was assessed under various operating conditions based on entering water temperature fluctuation. Because the cooling effectiveness of this type of system is highly dependent on the outside climate, its usefulness and suitability for different periods and zones must be investigated. The annual energy saving performance of the new system was estimated and compared to a conventional cooling system in terms of the integrated coefficient of performance, based on the hourly weather air temperature and water temperature bin data collected from 16 cities of different climate zones in South Korea. The experimental findings revealed that the novel hybrid internet data center cooling system showed a 67% annual operating performance over a conventional air source internet data center cooling system due to the adoption of a dam deep water source.
Keywords: internet data center; novel hybrid system; free cooling mode; forced cooling mode; ICOP (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/24/9274/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/24/9274/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:24:p:9274-:d:996186
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().