A Heuristic Approach to Optimal Crowbar Setting and Low Voltage Ride through of a Doubly Fed Induction Generator
Kumeshan Reddy and
Akshay Kumar Saha ()
Additional contact information
Kumeshan Reddy: Discipline of Electrical, Electronic and Computer Engineering, University of KwaZulu-Natal, Durban 4041, South Africa
Akshay Kumar Saha: Discipline of Electrical, Electronic and Computer Engineering, University of KwaZulu-Natal, Durban 4041, South Africa
Energies, 2022, vol. 15, issue 24, 1-36
Abstract:
In this paper, a heuristic approach to doubly fed induction generator (DFIG) protection and low voltage ride through (LVRT) is carried out. DFIG-based wind systems are rapidly penetrating the power generation section. Despite their advantages, their direct coupling grid makes them highly sensitive to symmetrical faults. A well-known solution to this is the crowbar method of DFIG protection. This paper provides a method to determine the optimal crowbar resistance value, to ensure a strong trade-off between the rotor current and DC voltage transients. Further, since the crowbar method requires disconnection from the grid, the linear quadratic regulator (LQR) is applied to the system. This is to ensure fault ride through compliance with recent grid code requirements. The well-known PSO, as well as the recently developed African vultures optimization algorithm (AVOA), was applied to the problem. The first set of results show that for severe symmetrical voltage dips, the AVOA provides a good option for crowbar magnitude optimization, whereas PSO performed better for moderately severe dips. Secondly, when the LQR was optimized via the AVOA, it exhibited superiority over the conventional PSO-based PI controller. This superiority was in terms of rotor current transient magnitude, DC voltage transient magnitude, and reactive power steady-state ripple and were in the order of 67.5%, 20.35%, and 37.55%, respectively. When comparing the crowbar method and the LQR, it was observed that despite the LQR exhibiting superiority in terms of transient performance, the crowbar method offered a unanimously superior settling time.
Keywords: doubly fed induction generator; optimization methods; algorithms; crowbar; linear quadratic regulator (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/24/9307/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/24/9307/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:24:p:9307-:d:997382
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().