Seasonal Air Quality in Bedrooms with Natural, Mechanical or Hybrid Ventilation Systems and Varied Window Opening Behavior-Field Measurement Results
Magdalena Baborska – Narożny and
Maria Kostka ()
Additional contact information
Magdalena Baborska – Narożny: Faculty of Architecture, Wrocław University of Science and Technology, ul. Bolesława Prusa 53/55, 50-317 Wrocław, Poland
Maria Kostka: Department of Air Conditioning, Heating, Gas Engineering and Air Protection, Wrocław University of Science and Technology, Norwida St. 4/6, 50-373 Wroclaw, Poland
Energies, 2022, vol. 15, issue 24, 1-17
Abstract:
The article presents the results of measurements of temperature, relative humidity and CO 2 concentration in six single-family houses’ bedrooms located in Poland, in Wrocław and vicinity, during two climatic seasons: summer–autumn and winter. Two buildings with natural ventilation (NV) were tested, three with mechanical ventilation with heat recovery (MV) and one with hybrid ventilation (HV)—mixed mode natural and mechanical. The behavior of residents regarding opening windows was analyzed and the influence of the changing internal and external conditions on their active reactions was examined. The analysis confirms and adds to the global discourse on the key impact of user behavior on securing healthy indoor air quality in housing, regardless of ventilation system or building energy standard. A disconnect exists between the observed window opening practices and typical design principles, assuming adjustment to a given ventilation system or changing weather conditions. The observations showed that in both analyzed seasons it was possible to obtain a good quality internal environment, in terms of CO 2 level, regardless of the ventilation system used in the building. However, unfavorable results were observed for one bedroom, in which the inhabitants do not adapt their behavior to local technical conditions. Taking into account the level of relative humidity (RH), much higher values were observed in the NV bedrooms in both analyzed periods. The obtained results were divided into IAQ classes in accordance with the EN 16798-1. The recorded values of the internal temperature confirm the significant influence of the location of the room in the building and the actions taken by the residents.
Keywords: bedroom ventilation; indoor air quality; window opening behavior; hybrid ventilation; MVHR; natural ventilation; housing (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/24/9328/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/24/9328/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:24:p:9328-:d:998391
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().