EconPapers    
Economics at your fingertips  
 

Application of Real Options Approach to Analyse Economic Efficiency of Power Plant with CCS Installation under Uncertainty

Janusz Sowinski
Additional contact information
Janusz Sowinski: Faculty of Electrical Engineering, Czestochowa University of Technology, ul. J.H. Dąbrowskiego 69, 42-201 Częstochowa, Poland

Energies, 2022, vol. 15, issue 3, 1-17

Abstract: The main goal of this article is to build a decision model for an investment involving the addition of a CCS (Carbon dioxide Capture and Storage) installation in an existing conventional power plant. The application of CCS systems in coal and gas power plants involves large capital expenditures and an increase in operating costs. The lack of upgrade modernisation and environmentally friendly investments in this type of power plant generates the additional costs of the purchase of emission allowances. An analysis of the impact of the addition of a CCS installation to an existing coal power plant on the costs of electricity generation is presented. Based on the accessible technical and economic data, a concept has been framed and an original decision-making model has been developed for an investment consisting in constructing a CCS installation in an existing power plant. A novelty of the paper is the presented proprietary decision-making model in conditions of uncertainty using the real options approach. Stochastic state variables are included in the model: the price of the CO 2 emission allowance, the unit costs of capturing, transporting, storing and stockpiling CO 2 and the unit costs of electricity generation. It is assumed that the time curves of the state variables are described by equations of geometric Brownian motions. The values of standard deviations in the equations are measures of uncertainty. The value of the retrofit option is defined as the maximum value from the expected net present value. From the dynamic optimisation equation, resulting from Bellman’s principle of optimality, it results that the retrofit option must satisfy the differential equation. The calculations were made for a specific, commercially applicable case of CCS technology in order to present the model’s capabilities. The analyses’ results and conclusions are presented.

Keywords: power system economics; carbon dioxide capture and storage; random processes; dynamic optimization; uncertainty (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (3)

Downloads: (external link)
https://www.mdpi.com/1996-1073/15/3/1050/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/3/1050/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:3:p:1050-:d:739145

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:15:y:2022:i:3:p:1050-:d:739145