Abstract:
Evaporators used in organic Rankine cycles (ORC) are designed using existing flow boiling correlations that are mainly based on HVAC&R data. However, the ORC evaporators employed in the industry typically have larger diameters and operational conditions at higher reduced pressures compared to the HVAC&R applications. The present study presents the results of flow boiling heat transfer experiments in operational conditions that are representative for an industrial waste heat recovery low-temperature ORC’s evaporator tube, by being performed at high reduced pressures and in a large-diameter horizontal tube with R245fa as working fluid. The measurements are performed within a range of mass flux, saturation temperature and heat flux at 83–283 kg/m 2 s, 85–120 °C (8.9–19.2 bar) and 17–29 kW/m 2 , respectively. Test section is a round and plain horizontal carbon steel tube with 21 mm I.D., 2.5 m length. 513 local two-phase heat transfer coefficients are recorded. The experimental results are compared with each other to reveal heat transfer coefficient trends with respect to varying experimental conditions. Four distinctive heat transfer zones are observed, namely, the nucleate boiling dominant (NBD) zone, weakening nucleate boiling dominance (WNBD) zone, flow boiling zone (FBZ) and the dry-out zone (DOZ). Heat transfer coefficient vs vapor quality trends partly resembled CO 2 flow boiling results reported in the literature. Two flow boiling correlations moderately predicted the data.
Keywords: flow boiling heat transfer; R245fa; high reduced pressures; large diameter tube; ORC; evaporator design (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/3/864/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/3/864/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:3:p:864-:d:733296
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().