Numerical Feasibility Study of Self-Regulating Radiant Ceiling in Combination with Diffuse Ceiling Ventilation

Marie Rugholm Krusaa and Christian Anker Hviid
Additional contact information
Marie Rugholm Krusaa: Department of Civil Engineering, Technical University of Denmark, Brovej, Building 118, DK-2800 Kgs. Lyngby, Denmark
Christian Anker Hviid: Department of Civil Engineering, Technical University of Denmark, Brovej, Building 118, DK-2800 Kgs. Lyngby, Denmark

Energies, 2022, vol. 15, issue 4, 1-31

Abstract: A focus on indoor comfort and tightening targets for energy savings in buildings presents new opportunities for heating, ventilation, and air-conditioning products (HVAC). This paper presents a novel comfort solution that integrates a suspended radiant ceiling with diffuse ventilation, dubbed HVACeiling. In combination with the concrete slab, the HVACeiling has the potential to provide thermal comfort with minimal temperature offset, which supports operation of the heating and cooling system at temperatures very close to the room comfort temperature. The paper presents a parametric numerical study of the concept in a simplified two-pipe layout with fixed flow and fixed temperatures. First, the analysis was focused on different internal and solar loads, heat losses, and climatic locations with the aim of assessing the potential of self-regulation, i.e., no active controls, thermal comfort, ability to reduce peak loads and the consequential building design considerations. Secondly, the purpose was to analyse the concept in a generic office building with five offices and one meeting room and compare it to other HVAC solutions. The whole-year analyses of heating, cooling, energy performance, and thermal comfort were done using the building performance simulation software IDA ICE. It was found that it was possible to create thermal comfort in Paris, Munich, and Copenhagen with water circulating constantly with fixed temperatures of 20–24 °C without controls and with window sizes from 15 to 30% of the floor area. The studies showed that the HVACeiling reduced the operative peak temperatures on the warmest days in comparison with a standard radiant ceiling with mixing ventilation by 1 K. Compared to all-air solutions, the HVACeiling reduced the yearly energy consumption by 20–30% and the peak power in summer up to 69%. This study indicates that thermal comfort is achievable in a European context even at very small temperature offsets, which supports the use of more renewable energy sources.

Keywords: heating; cooling; radiant ceilings; diffuse ventilation; energy saving (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/15/4/1319/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/4/1319/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:4:p:1319-:d:747334

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:15:y:2022:i:4:p:1319-:d:747334