EconPapers    
Economics at your fingertips  
 

The Effect of DC Voltage Pre-Stress on the Breakdown Voltage of Air under Composite DC and LI Voltage and Test Circuit: Design and Application

Mehmet Murat Ispirli, Özcan Kalenderli, Florian Seifert, Michael Rock and Bülent Oral
Additional contact information
Mehmet Murat Ispirli: Group for Lightning and Surge Protection, Technische Universität Ilmenau, 98693 Ilmenau, Germany
Özcan Kalenderli: Electrical Engineering Department, Istanbul Technical University, 34469 Istanbul, Turkey
Florian Seifert: Research Unit High-Voltage Technologies, Technische Universität Ilmenau, 98693 Ilmenau, Germany
Michael Rock: Group for Lightning and Surge Protection, Technische Universität Ilmenau, 98693 Ilmenau, Germany
Bülent Oral: Electrical-Electronic Engineering Department, Marmara University, 34722 Istanbul, Turkey

Energies, 2022, vol. 15, issue 4, 1-23

Abstract: The use of HVDC systems is increasing in number due to technological innovations, increasing power capacity and increasing customer demand. The characteristics of insulation systems under composite DC and LI voltage must be examined and clarified. In this study, firstly, experimental circuits were designed to generate and measure composite DC and LI high voltage using a simulation program. The coupling elements used were chosen according to simulation results. Afterward, experimental circuits were established in the laboratory according to the simulation results of the designed experimental circuit. Then, breakdown voltages under composite DC and LI voltage for less uniform and non-uniform electric fields were measured with four different electrode systems for positive and negative DC voltage pre-stresses with different amplitudes. The 50% breakdown voltage was calculated using the least-squares method. Finally, 3D models were created for the electrode systems used in the experiments using the finite element method. The efficiency factors of electrode systems calculated with the FEM results were correlated with the experimental breakdown voltage results. Thus, the breakdown behavior of air under bipolar and unipolar composite voltages (CV) was investigated. In conclusion, the experimental results showed that very fast polarity change in bipolar CV causes higher electrical stress compared to unipolar CV.

Keywords: breakdown voltage of air; composite voltage; HVDC; lightning impulse; HV test circuit (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/15/4/1353/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/4/1353/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:4:p:1353-:d:748499

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19