High Frequency Resonance Suppression Strategy of Three-Phase Four-Wire Split Capacitor Inverter Connected to Parallel Compensation Grid
Guoli Feng,
Zhihao Ye,
Yihui Xia,
Heng Nian,
Liming Huang and
Zerun Wang
Additional contact information
Guoli Feng: College of Electrical Engineering, Navel University of Engineering, Jiefang Road 717, Wuhan 430030, China
Zhihao Ye: College of Electrical Engineering, Navel University of Engineering, Jiefang Road 717, Wuhan 430030, China
Yihui Xia: College of Electrical Engineering, Navel University of Engineering, Jiefang Road 717, Wuhan 430030, China
Heng Nian: College of Electrical Engineering, Zhejiang University, Zheda Road 38, Hangzhou 310027, China
Liming Huang: College of Electrical Engineering, Navel University of Engineering, Jiefang Road 717, Wuhan 430030, China
Zerun Wang: College of Electrical Engineering, Navel University of Engineering, Jiefang Road 717, Wuhan 430030, China
Energies, 2022, vol. 15, issue 4, 1-20
Abstract:
With the continuous penetration and development of renewable energy power generation, the distributed grid and the microgrid are becoming increasingly important in modern power systems. In distribution networks and the microgrid, the grid impedance is comparatively large and cannot be ignored. Usually, the parallel compensation is used to improve the grid quality. In the grid with parallel compensation, the large phase angle difference between the impedance of the grid-connected inverter and the impedance of the grid at amplitude intersection will result in high frequency resonance (HFR). Because the inverter shows filter characteristics due to limited bandwidth of the controller, the parallel compensation grid, respectively, performs as the capacitance characteristic and inductance characteristic in different high frequency range. Compared with the three-phase, three-wire system, an additional zero-sequence path exists in the three-phase four-wire split capacitor inverter (TFSCI) system, so that the existing high frequency resonance suppression methods will be not effective. Since the zero-sequence component is neglected, HFR will also occur, in addition to the positive-sequence component and the negative-sequence component. Therefore, in order to suppress the high frequency resonance caused by positive-sequence, negative-sequence and zero-sequence components, an impedance reshaping strategy based on current feedback is proposed in this paper. This proposed method can reshape the amplitude and phase of the inverter impedance in a high frequency range without affecting the performance of the fundamental frequency control and ensure that the inverter contains a sufficient phase margin. Additionally, the proposed method can reshape the impedance of TFSCI within a wide frequency range, which makes it able to cope with the challenge of the parallel compensation degree change. Theoretical analysis and experiments verify the availability of the proposed control strategy.
Keywords: three-phase four-wire split capacitor grid-connected inverter; impedance reshaping; high frequency resonance (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/4/1486/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/4/1486/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:4:p:1486-:d:751595
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().