Abstract:
Modelling of thermal energy storage (TES) systems is a complex process that requires the development of sophisticated computational tools for numerical simulation and optimization. Until recently, most modelling approaches relied on analytical methods based on equations of the physical processes that govern TES systems’ operations, producing high-accuracy and interpretable results. The present study tackles the problem of modelling the temperature dynamics of a TES plant by exploring the advantages and limitations of an alternative data-driven approach. A hybrid bimodal LSTM (H2M-LSTM) architecture is proposed to model the temperature dynamics of different TES components, by utilizing multiple temperature readings in both forward and bidirectional fashion for fine-tuning the predictions. Initially, a selection of methods was employed to model the temperature dynamics of individual components of the TES system. Subsequently, a novel cascading modelling framework was realised to provide an integrated holistic modelling solution that takes into account the results of the individual modelling components. The cascading framework was built in a hierarchical structure that considers the interrelationships between the integrated energy components leading to seamless modelling of whole operation as a single system. The performance of the proposed H2M-LSTM was compared against a variety of well-known machine learning algorithms through an extensive experimental analysis. The efficacy of the proposed energy framework was demonstrated in comparison to the modelling performance of the individual components, by utilizing three prediction performance indicators. The findings of the present study offer: (i) insights on the low-error performance of tailor-made LSTM architectures fitting the TES modelling problem, (ii) deeper knowledge of the behaviour of integral energy frameworks operating in fine timescales and (iii) an alternative approach that enables the real-time or semi-real time deployment of TES modelling tools facilitating their use in real-world settings.
Keywords: bi-modal LSTM; cascading energy framework; district heating; thermal energy storage (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/6/1959/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/6/1959/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:6:p:1959-:d:766211
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().