Analysis of Fault Characteristics of Distribution Network with PST Loop Closing Device under Small Current Grounding System
Zhi Xu,
Jianxiong Tang,
Yupeng Jiang,
Risheng Qin,
Hongsheng Ma,
Yongchun Yang and
Chengyong Zhao
Additional contact information
Zhi Xu: Electric Power Research Institute, Yunnan Power Grid Co., Ltd., Kunming 650217, China
Jianxiong Tang: State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Baoding 071003, China
Yupeng Jiang: Yunnan Power Grid Co., Ltd., Kunming Power Supply Bureau, Kunming 650032, China
Risheng Qin: Electric Power Research Institute, Yunnan Power Grid Co., Ltd., Kunming 650217, China
Hongsheng Ma: Electric Power Research Institute, Yunnan Power Grid Co., Ltd., Kunming 650217, China
Yongchun Yang: State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Baoding 071003, China
Chengyong Zhao: State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Baoding 071003, China
Energies, 2022, vol. 15, issue 7, 1-17
Abstract:
With the rapid development of cities and the increasing complexity of distribution network systems, the cableization of transmission lines and the diversification of power users have brought new challenges to the supply reliability of distribution networks. Short-time outages caused by power outages and maintenance are one of the factors that affect the reliability of the power supply in the distribution network. The non-stop load transfer through a phase-shifting transformer (PST) operation can effectively improve the reliability of power supply to complex distribution systems. Considering the operation mode and structure form and fault type of the urban distribution network in China, comparing and analyzing the applicable scenarios of different neutral grounding methods, and based on the structure and zero sequence path characteristics of PST, an improved PST-based phase shifting and grounding transformer loop closing device with low power consumption is proposed. The fault characteristics of the PST-based loop closing device under the small current grounding system are also analyzed by the sequence component method, and, finally, the effectiveness of the phase-shifting and grounding transformer device is verified by simulation under PSCAD/EMTDC for fault routing and protection configuration of the urban distribution network in China.
Keywords: small current grounding system; phase-shifting transformer; phase-shifting and grounding transformer; distribution network; loop closing device (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/7/2307/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/7/2307/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:7:p:2307-:d:776837
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().