EconPapers    
Economics at your fingertips  
 

Power Flow Optimization and Economic Analysis Based on High Voltage Phase Shifting Transformer

Mengze Yu, Jiaxin Yuan, Zuohong Li, Feng Li, Xinyi Yang, Weizhe Zhang, Shunkai Xu and Jiajun Mei
Additional contact information
Mengze Yu: Grid Planning & Research Center, Guangdong Power Grid Corporation, CSG, Shuijungang No. 8, Dongfeng East Road, Guangzhou 510080, China
Jiaxin Yuan: School of Electrical and Automation, Wuhan University, No. 299, Bayi Street, Wuchang District, Wuhan 430072, China
Zuohong Li: Grid Planning & Research Center, Guangdong Power Grid Corporation, CSG, Shuijungang No. 8, Dongfeng East Road, Guangzhou 510080, China
Feng Li: Grid Planning & Research Center, Guangdong Power Grid Corporation, CSG, Shuijungang No. 8, Dongfeng East Road, Guangzhou 510080, China
Xinyi Yang: School of Electrical and Automation, Wuhan University, No. 299, Bayi Street, Wuchang District, Wuhan 430072, China
Weizhe Zhang: School of Electrical and Automation, Wuhan University, No. 299, Bayi Street, Wuchang District, Wuhan 430072, China
Shunkai Xu: School of Electrical and Automation, Wuhan University, No. 299, Bayi Street, Wuchang District, Wuhan 430072, China
Jiajun Mei: School of Electrical and Automation, Wuhan University, No. 299, Bayi Street, Wuchang District, Wuhan 430072, China

Energies, 2022, vol. 15, issue 7, 1-21

Abstract: With the development of power systems, the power flow problem of transmission line is becoming more and more prominent. This paper presents a power flow regulation method based on phase shifting transformer (PST). Firstly, the working principle and performance of PST are analyzed. Then, the simulation model of BPA multi node system is established. PST access reduces the line imbalance to less than 8%. On this basis, considering the influence of saturation effect and leakage reactance, a PST suitable for 220 kV power grid is designed. Three different working conditions are simulated by PSCAD software. Under normal working conditions and N-1 conditions, PST can increase the transmission limit of the ring network section by more than 20%. When a short-circuit fault occurs, PST can also suppress the fault current. For 220 kV practical projects, unified power flow controller (UPFC) has faster response speed and stronger performance, but PST is more economical and reliable, and the equipment cost is 49.86% lower than that of UPFC. The power flow regulation method based on PST has good steady-state effect. It can improve the utilization efficiency of power grid assets and optimize the power flow distribution in a short time and at low cost.

Keywords: phase shifting transformer; leakage reactance; transmission line; power flow control (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1996-1073/15/7/2363/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/7/2363/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:7:p:2363-:d:778375

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:15:y:2022:i:7:p:2363-:d:778375