Simulations of emergency states and tests of resistance of electrical devices to emergencies are performed in specialized high-power laboratories, the so-called short-circuit laboratories. For most electrical power devices, such measurements are required by international standards. The basic equipment of short-circuit testing laboratories consists of current transformers for measuring short-circuit currents. These transformers should not only enable the accurate conversion of sinusoidal currents—which is typical for conventional current transformers, but also asymmetrical short-circuit currents containing an aperiodic component, which classic current transformers cannot reproduce. Therefore, manufacturers and designers try to meet the market demands and design these special class 0.2 current transformers. To meet the high technical requirements, the field-circuit method with three-dimensional space–time analysis of electromagnetic fields was used during design, considering physical phenomena in ferromagnetic cores (i.e., hysteresis and eddy current losses) and the load of the secondary winding of the current transformer by the measurement system. The article presents simulations of secondary currents for the short-circuit current transformer model, and the results were confirmed by measurements and oscillograms of the currents flowing in the windings of the real model. The prototype of the designed short-circuit transformer meets the IEC/EN standard requirements. When measuring harmonic currents, the transformation errors meet the requirements of class 0.2. During the short-circuit current waveforms, the maximum instantaneous peak error does not exceed 1% of the error for all the subsequent maxima of the current waveform during the specified transient switching cycle. In comparison, the standard allows this error to be 10%.
Keywords: cascade current transformers; short-circuit current measurements; transient state; finite element method (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/8/2925/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/8/2925/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:8:p:2925-:d:795010
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().