Electromagnetic and Thermal Analysis of 225 kW High-Speed PMSM for Centrifugal Blower Applications
Usman Abubakar,
Xiaoyuan Wang,
Sayyed Haleem Shah,
Lixin Wang and
Aminu Farouk
Additional contact information
Usman Abubakar: School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China
Xiaoyuan Wang: School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China
Sayyed Haleem Shah: School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China
Lixin Wang: School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China
Aminu Farouk: School of Nuclear Science and Technology, Harbin Engineering University, Harbin 150001, China
Energies, 2022, vol. 15, issue 9, 1-27
Abstract:
In order to make centrifugal blowers environmentally friendly, machines with a lighter weight and a more compact size are required. Thus, the axial length of the machine needs to be minimized within the diameter limit. However, in the design methodology, losses and thermal study become very significant; thus, losses increase significantly to achieve the desired output power when the volume is excessively reduced. Moreover, due to the machine’s compact size, heat is concentrated rapidly without adequate cooling. It might lead to a temperature rise of the critical part of the machine above the safe limit, such as winding, thereby affecting its lifespan. This study considers the 225 kW high-speed permanent magnet synchronous machine (HSPMSM) with the forced air cooling axial ventilation system (FACAVS) used in centrifugal blower applications. Firstly, four different analytical models (A2–A5) in the electromagnetic analysis are derived by minimizing the initial machine’s (A1) axial length to achieve a lighter weight and more compact size with better electromagnetic performance. The best among analytical models is chosen as the A4 model with a lighter weight and a more compact structure in addition to higher torque density than A1, A2, and A3 models, and higher efficiency than A1, A2, A3, and A5 models by HSPMSM’s, optimal geometric design, and optimal material choice, respectively. Secondly, LPTN is designed to predict the entire analytical model’s thermal behavior in the thermal analysis. Investigation shows that winding temperature rises from the A4 model is maintained below winding insulation by the determined optimal axial ventilation parameters from the sensitivity analysis. Finally, different analytical models are prototyped and tested. The comparisons between predicted electromagnetic performance, winding temperature rise, and test results were carried out, and the results were found to agree with each other consistently.
Keywords: electromagnetic analysis; thermal network; PMSM; centrifugal blower (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/9/3370/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/9/3370/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:9:p:3370-:d:809059
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().