Effects of Internal Heat Exchanger on Two-Stage Compression Trans-Critical CO 2 Refrigeration Cycle Combined with Expander and Intercooling
Benlin Shi,
Muqing Chen,
Weikai Chi,
Qichao Yang (),
Guangbin Liu,
Yuanyang Zhao and
Liansheng Li
Additional contact information
Benlin Shi: College of Electromechanical Engineering, Qingdao University of Science and Technology, Qingdao 266100, China
Muqing Chen: College of Electromechanical Engineering, Qingdao University of Science and Technology, Qingdao 266100, China
Weikai Chi: College of Electromechanical Engineering, Qingdao University of Science and Technology, Qingdao 266100, China
Qichao Yang: College of Electromechanical Engineering, Qingdao University of Science and Technology, Qingdao 266100, China
Guangbin Liu: College of Electromechanical Engineering, Qingdao University of Science and Technology, Qingdao 266100, China
Yuanyang Zhao: College of Electromechanical Engineering, Qingdao University of Science and Technology, Qingdao 266100, China
Liansheng Li: College of Electromechanical Engineering, Qingdao University of Science and Technology, Qingdao 266100, China
Energies, 2022, vol. 16, issue 1, 1-16
Abstract:
Because of the limitations of traditional refrigerants, the application of trans-critical CO 2 technology in domestic gas conditioners and other fields is becoming increasingly popular. This paper proposes a new CO 2 trans-critical refrigeration system. Combining the internal heat exchanger and expander components, as well as the two-stage compression cycle, we analyzed the effectiveness of the expander, internal heat exchanger, and intercooling on system performance under various operating conditions in terms of energy, exergy analysis, and optimal discharge pressure. The system performance can be changed by changing the cycle conditions and internal heat exchanger effectiveness, which reduces system power consumption and the percentage of exergy losses of gas cooler components. Compared to the single-stage compression with expander cycle, the systems cycle power consumption is reduced by 2–15.7% and the maximum system COP is increased by 2.93–6.93%. From the view of energy effectiveness, the system’s maximum COP increases by 3.9% and the percentage of exergy losses of gas cooler decreases by 22.5% with the effectiveness of internal heat exchanger varying. The addition of an internal heat exchanger has resulted in improved system performance, which is important for providing a relevant cycle model for the application.
Keywords: CO 2 refrigeration cycle; internal heat exchanger ( IHX ); expander; two-stage compression; intercooling; coefficient of performance (COP) (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/16/1/115/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/1/115/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2022:i:1:p:115-:d:1011528
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI