A Novel Method for Detection and Location of Series Arc Fault for Non-Intrusive Load Monitoring
Krzysztof Dowalla (),
Piotr Bilski,
Robert Łukaszewski,
Augustyn Wójcik and
Ryszard Kowalik
Additional contact information
Krzysztof Dowalla: Institute of Radioelectronics and Multimedia Technologies, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw, Poland
Piotr Bilski: Institute of Radioelectronics and Multimedia Technologies, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw, Poland
Robert Łukaszewski: Institute of Radioelectronics and Multimedia Technologies, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw, Poland
Augustyn Wójcik: Institute of Electrical Power Engineering, Warsaw University of Technology, Koszykowa 75, 00-662 Warsaw, Poland
Ryszard Kowalik: Institute of Electrical Power Engineering, Warsaw University of Technology, Koszykowa 75, 00-662 Warsaw, Poland
Energies, 2022, vol. 16, issue 1, 1-23
Abstract:
Series arc faults cause the majority of household fires involving electrical failures or malfunctions. Low-fault current amplitude is the reason for the difficulties faced in implementing effective arc detection systems. The paper presents a novel arc detection and faulty line identification method. It can be easily used in the low-voltage Alternate Current (AC) household network for arc detection in the Non-Intrusive Load Monitoring (NILM). Unlike existing methods, the proposed approach exploits both current and voltage signal time domain analysis. Experiments have been conducted with up to six devices operating simultaneously in the same circuit with an arc fault generator based on the IEC 62606:2013 standard. Sixteen time-domain features were used to maximize the arc-fault detection accuracy for particular appliances. Performance of the random forest classifier for arc fault detection was evaluated for 28 sets of features with five different sampling rates. For the single period analysis arc, detection accuracy was 98.38%, with F-score of 0.9870, while in terms of the IEC 62606:2013 standard, it was 99.07%, with F-score of 0.9925. Location of a series arc fault (line selection) was realized by identifying devices powered by the faulty line. The line selection was based on the Mean Values of Changes feature vector ( MVC 50 ), calculated for absolute values of differences between adjacent current signal periods during the arc fault. The fault location accuracy was 93.20% for all cases and 98.20% for cases where the arc fault affected a single device.
Keywords: arc fault detection; fault location; line selection; NILM; non-intrusive load monitoring; series arc; smart grid; smart metering (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/16/1/171/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/1/171/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2022:i:1:p:171-:d:1013319
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().