De-Loaded Technique Enhanced by Fuzzy Logic Controller to Improve the Resilience of Microgrids Based on Wind Energy and Energy Storage Systems
Assia Mahrouch,
Mohammed Ouassaid,
Zineb Cabrane and
Soo Hyoung Lee ()
Additional contact information
Assia Mahrouch: Engineering for Smart and Sustainable Systems Research Center, Mohammadia School of Engineers, Mohammed V University in Rabat, Rabat 10090, Morocco
Mohammed Ouassaid: Engineering for Smart and Sustainable Systems Research Center, Mohammadia School of Engineers, Mohammed V University in Rabat, Rabat 10090, Morocco
Zineb Cabrane: Research, Development and Innovation Laboratory, Mundiapolis University, Casablanca 20180, Morocco
Soo Hyoung Lee: Department of Electrical and Control Engineering, Mokpo National University, Mokpo 58554, Republic of Korea
Energies, 2022, vol. 16, issue 1, 1-16
Abstract:
Wind turbine generators (WTGs) are highly sensitive to the disturbances of the grid and tend to disconnect quickly during a voltage dip (when the voltage value is less than 80% of the nominal voltage) or when the frequency is greatly changed. As an increasing number of permanent magnet synchronous generators (PMSGs) are incorporated into the modern power grid, system operators expect PMSG-WT to play an active role in low-voltage ride-through (LVRT) and primary frequency regulation (PFR). Consequently, PMSG-WTs must be capable of supplying additional active power in response to changes in system voltage and frequency. In this context, a new de-loaded technique enhanced by a fuzzy-logic controller is suggested to develop the PMSG-pitch angle control (PMSG-PAC). The studied MG consists of a wind farm (WF), variable load, and a battery energy storage system (BESS). The WF contains five PMSG-WTs which are considered to be the principal resource. The proposed DT-FLC ensures maximum aerodynamic reserve power for the plant, enhances its capability to regulate the PAC, adjusts the WTG drop in response to the wind speed, and increases the resilience of the PMSG-WT in the presence of low voltage. Moreover, the PFR is significantly improved in terms of controlling the PAC (−0.0007 Hz) which meets the frequency maximum droop recommended by the IEEE Std 1547-2018 and the Moroccan grid code, −3 Hz and −2.5 Hz, respectively.
Keywords: microgrid resilience; low-voltage ride-through; primary frequency regulation; permanent magnet synchronous generator; de-loaded technique; fuzzy-logic controller; pulse width modulation (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/16/1/291/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/1/291/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2022:i:1:p:291-:d:1016701
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().