Investigation of Thermo-Hydraulic Performances of Artificial Ribs Mounted in a Rectangular Duct
B. Varun Kumar,
P. Rajesh Kanna,
G. Manikandan,
Dawid Taler,
Jan Taler (),
Tomasz Sobota and
Marzena Nowak-Ocłoń
Additional contact information
B. Varun Kumar: Velammal College of Engineering and Technology, Madurai 625107, India
P. Rajesh Kanna: CO 2 Research and Green Technologies Centre, Vellore Institute of Technology, Vellore 632014, India
G. Manikandan: Velammal College of Engineering and Technology, Madurai 625107, India
Dawid Taler: Department of Thermal Processes, Air Protection and Waste Management, Cracow University of Technology, 31-155 Cracow, Poland
Jan Taler: Department of Energy, Cracow University of Technology, 31-864 Cracow, Poland
Tomasz Sobota: Department of Thermal Processes, Air Protection and Waste Management, Cracow University of Technology, 31-155 Cracow, Poland
Marzena Nowak-Ocłoń: Department of Energy, Cracow University of Technology, 31-864 Cracow, Poland
Energies, 2023, vol. 16, issue 11, 1-21
Abstract:
This research investigates the fluid flow characterization and thermohydraulic performances (THP) of rib surfaces, using computational and experimental methods. ANSYS computational fluid dynamics (CFD) software was used to predict and validate the findings in the experimental setup. Artificial rib surfaces, including polygonal and forward trapezoidal-shaped ribs, were placed in the absorber plate at different relative pitch distances (p/e) = 6.7, 10, 13.4 and relative height (e/d) = 20, and the mass flow rate of air (working fluid) varied at Reynolds numbers ranging from 2000 to 20,000. According to the validation results, the RNG renormalization k-ε model was selected for the investigation. The results show that strong turbulence occured closer to the wall surface and behind the rib surface, enhancing thermal performances due to the sharp edge shape of the rib. A polygonal rib with a pitch distance of p/e = 6.7 achieved a higher Nusselt number (Nu) and thermohydraulic performance of 2.95 at Re 4000. An empirical correlation between the Nusselt number (Nu) and friction factor ( f ) was developed using linear regression analysis and was compared with the predicted values. The comparison results show a close range of ±8% between the experimental and predicted values.
Keywords: polygonal rib; forward trapezoidal rib; THP; solar air heater (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/16/11/4404/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/11/4404/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:11:p:4404-:d:1159424
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().