A Compact High-Stability Nanosecond Pulse Test System Using Corona-Stabilized Switch and Coaxial Resistance Divider
Jinru Sun,
Qin Qing,
Haoliang Liu,
Xueling Yao (),
Zijiao Jiao and
Yiheng Wu
Additional contact information
Jinru Sun: State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
Qin Qing: State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
Haoliang Liu: State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
Xueling Yao: State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
Zijiao Jiao: State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
Yiheng Wu: State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
Energies, 2023, vol. 16, issue 11, 1-18
Abstract:
Due to the lack of a standard nanosecond high-voltage pulse generator for sensor calibration, a high-stability nanosecond high-voltage pulse test system was developed in terms of circuit analysis, structural design, and performance test. By establishing the equivalent circuit model of the nanosecond pulse generator, the circuit component parameters of the five-stage Marx loop and the one-stage compression steepening unit were simulated. The influence of the action performance of the steepening gap on the characteristics of output nanosecond pulse was analyzed. The nanosecond pulse test system was established through the structural design of the nanosecond pulse-generating circuit, the development of a high-performance corona-stabilized switch, and the measurement of a fast-response resistance divider made of metal oxide thin-film resistors. The nanosecond pulse test system has the capability to output a double exponential nanosecond pulse voltages in the amplitude range of 10–60 kV with a rise time of 2.3 ± 0.5 ns and a half-peak time of 23 ± 5 ns. In addition, the output pulse voltage has a high consistency and stability in the full amplitude range. The maximum relative standard deviation of the peak value is 1.517%, and the relative standard uncertainty is less than 5‰.
Keywords: nanosecond pulse generator; circuit simulation; resistance divider; calibration method; improved stability (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/16/11/4534/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/11/4534/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:11:p:4534-:d:1164453
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().