EconPapers    
Economics at your fingertips  
 

Determination of Dielectric Models Based on Effective Multi-Exponential Fittings

Jedsada Raxsa, Phethai Nimsanong, Thanatorn Mai-Eiam and Peerawut Yutthagowith ()
Additional contact information
Jedsada Raxsa: Department of Electrical Engineering, School of Engineering, King Mongkut’s Institute of Technology Ladkrabang, Bangkok 10520, Thailand
Phethai Nimsanong: Metropolitan Electricity Authority, Bangkok 10110, Thailand
Thanatorn Mai-Eiam: Department of Electrical Engineering, School of Engineering, King Mongkut’s Institute of Technology Ladkrabang, Bangkok 10520, Thailand
Peerawut Yutthagowith: Department of Electrical Engineering, School of Engineering, King Mongkut’s Institute of Technology Ladkrabang, Bangkok 10520, Thailand

Energies, 2023, vol. 16, issue 12, 1-21

Abstract: In high-voltage (HV) transmission and distribution systems, HV apparatuses are subjected to electrical, thermal, and mechanical stresses that deteriorate the insulation performance. The polarization and depolarization current (PDC) measurement is an effective tool used for evaluating insulation performances. The depolarization current represented by the summation of the discharge currents with the different time constants can be utilized for the development of the dielectric model based on the extended Debye’s model (EDM). This paper presents effective techniques for determining the dielectric model. Iterative approaches with predetermination of the time constants and least squares methods (either linear ordinary or percentage ones) were utilized to fit the depolarization current in the form of multi-exponential functions. The fitting parameters determined by the proposed method with the linear ordinary least squares (OLLS) method and provided by commercial software agree very well only in the high current and beginning range. Application of the linear percentage least squares (PLLS) method shows better accuracy than that of the OLLS method, and the deviation from the measured one in the low current range and the late measuring time were reduced significantly. The fitted current by this proposed technique with the PLLS method agrees well with the measured current throughout the whole recording time, even in the low current and late time range. From the accurately fitted currents, the dielectric model and the dielectric loss factors can be determined precisely, and the insulation condition of HV equipment can be evaluated properly.

Keywords: dielectric loss factor; extended Debye’s model; multi-exponential function fit; PDC measurement; percentage least squares method (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/16/12/4615/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/12/4615/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:12:p:4615-:d:1167727

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:16:y:2023:i:12:p:4615-:d:1167727