Anti-Condensation Temperature Control Strategy of the Concrete Radiant Roof
Bobo Zhang (),
Qin Sun,
Lin Su,
Kaijun Dong (),
Weimin Luo,
Haifeng Guan,
Zhenhua Shao and
Wei Wu
Additional contact information
Bobo Zhang: Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou 510640, China
Qin Sun: Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou 510640, China
Lin Su: Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou 510640, China
Kaijun Dong: Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou 510640, China
Weimin Luo: Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou 510640, China
Haifeng Guan: Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou 510640, China
Zhenhua Shao: Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou 510640, China
Wei Wu: School of Energy and Environment, City University of Hong Kong, Hong Kong, China
Energies, 2023, vol. 16, issue 12, 1-14
Abstract:
Radiation cooling, as a new terminal mode that has been gradually emerging in recent years, has attracted more and more attention. However, the problem of condensation has become a vital bottleneck restricting the broad application of radiation-cooling technology. This paper used the numerical simulation method of Ansys Fluent to study the effect of different water supply parameters on the concrete radiant roof’s heat transfer performance, temperature uniformity analysis, and anti-condensation temperature control strategy. The accuracy of the simulation model was verified by comparing the numerical simulation values and measured values of temperature monitoring points. In thermal performance research, the inlet temperature significantly impacted the cooling capacity and radiant surface temperature compared with the inlet flow velocity. In the uniformity study, the distance between the serpentine pipes area and the concrete edge was easily neglected, which was also an important factor affecting the distribution of temperature uniformity. Regarding anti-condensation and performance improvement research, first supplying water at low temperatures and then dynamically adjusting high-temperature water could effectively avoid condensation and improve the radiant roof’s heat transfer performance. The research results could provide technical references for the practical application of radiation roof anti-condensation temperature control technology.
Keywords: radiation cooling; concrete radiant roof; serpentine pipe; anti-condensation; temperature control; computational fluid dynamics (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/16/12/4826/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/12/4826/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:12:p:4826-:d:1175296
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().