Parametric Study and Optimization of No-Blocking Heliostat Field Layout
Dhikra Derbal (),
Abdallah Abderrezak,
Seif Eddine Chehaidia,
Majdi T. Amin,
Mohamed I. Mosaad () and
Tarek A. Abdul-Fattah
Additional contact information
Dhikra Derbal: Research Laboratory of Industrial Risks, Non-Destructive Control and Operating Safety, Mechanical Engineering Department, Badji Mokhtar Annaba University, Annaba 23000, Algeria
Abdallah Abderrezak: Research Laboratory of Industrial Risks, Non-Destructive Control and Operating Safety, Mechanical Engineering Department, Badji Mokhtar Annaba University, Annaba 23000, Algeria
Seif Eddine Chehaidia: Département de Génie Mécanique, Ecole Nationale Polytechnique de Constantine (ENPC), Constantine 25000, Algeria
Majdi T. Amin: Mechanical Engineering Technology, Yanbu Industrial College (YIC), Royal Commission Yanbu Colleges & Institutes, Alnahdah, Yanbu Al Sinaiyah, Yanbu 46452, Saudi Arabia
Mohamed I. Mosaad: Electrical Engineering Department, Faculty of Engineering, Damietta University, Damietta 34511, Egypt
Tarek A. Abdul-Fattah: Department of Engineering Physics and Mathematics, Faculty of Engineering, Zagazig University, Zagazig 44519, Egypt
Energies, 2023, vol. 16, issue 13, 1-21
Abstract:
Generating electric power using solar thermal systems is effective, particularly for countries with high solar potential. In order to decide on a relevant location to implement the solar tower plant and develop the mathematical model of a no-blocking heliostat field, a meteorological assessment was discussed in this paper. In addition, a parametric study was examined to evaluate the effect of the designed parameters (heliostat size, heliostat height from the ground, tower height, receiver aperture, and the minimum radius) on the solar field’s performance. The preliminary solar field was then compared to the final design using the optimal design parameters. The obtained results showed that “Tamanrasset City” satisfied the necessary conditions for implementing a solar tower plant. According to preliminary solar field generation, no heliostat blocked its neighbor with a blocking efficiency of 100%. An analysis of its performance revealed that the optimized solar field would be capable of producing 15, 6571 MW, operating at an optical efficiency of 76.95%, and the enhancement rate of both efficiency and power output was 8.1%.
Keywords: heliostat; no-blocking; solar field; SolarPilot; solar thermal; tower (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/16/13/4943/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/13/4943/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:13:p:4943-:d:1179203
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().