EconPapers    
Economics at your fingertips  
 

Design and Internal Flow Characteristic Investigation of High-Temperature H 2 /Steam-Mixed Working Fluid Turbine

Liangchuan Wei, Bing Guo (), Nanyi Li and Zhonghao Heng
Additional contact information
Liangchuan Wei: School of Mechanical Engineering, Qinghai University, Xining 810000, China
Bing Guo: School of Mechanical Engineering, Qinghai University, Xining 810000, China
Nanyi Li: School of Mechanical Engineering, Qinghai University, Xining 810000, China
Zhonghao Heng: School of Mechanical Engineering, Qinghai University, Xining 810000, China

Energies, 2023, vol. 16, issue 13, 1-19

Abstract: In this paper, an improved RSM-CFD method is used to optimally design a mixed turbine of non-equilibrium condensing steam (NECS) and hydrogen (H 2 ), of which the response surface method (RSM) and computational fluid dynamics (CFD) are coupled to take into account the effects of the wet steam non-equilibrium condensation process of the multimixed working fluid. A single-stage H 2 /Steam (NEC)-mixed turbine was developed based on the improved RSM-CFD, and the effect mechanism of the H 2 component ratio (ω H2 ) on the flow characteristics, internal power, and isentropic efficiency within the turbine stage were investigated. The results show that the isentropic efficiency ( η ) increases with the increase in the hydrogen component ratio (ω H2 ), since hydrogen, as a non-condensable component, can inhibit the nucleation and growth of steam, reducing the pressure pulsation on the blade surface; furthermore, it accelerates the transport and diffusion of liquid droplets, inhibits the flow separation, and reduces the flow loss in the flow channel. However, the internal power of the turbine ( P ) tends to decrease with increasing ω H2 , since the increase in hydrogen reduces the pressure difference on the blade and lowers the torque of the fluid acting on the blade, and at the same time, the vortex and radial flow intensify, and the enthalpy drop inside the stage decreases. On this basis, the optimum operating conditions are found where the hydrogen component ratio (volume percent) ω H2 = 53%. Accordingly, the hydrogen component ratio should be maintained in the range of 38–68%, considering the work capacity and hydrogen yield of the mixed working fluid.

Keywords: high-temperature H 2 /steam-mixed working fluid; turbine design; flow characteristics; numerical simulation (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/16/13/5072/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/13/5072/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:13:p:5072-:d:1183898

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:16:y:2023:i:13:p:5072-:d:1183898