Evaluation of the Hygrothermal Conditions of a Typical Residential Building in the Azores Archipelago

João Malça (), Ricardo M. S. F. Almeida and José A. R. Mendes Silva
Additional contact information
João Malça: Coimbra Institute of Engineering (ISEC), Polytechnic Institute of Coimbra, Rua Pedro Nunes, Quinta da Nora, 3030-199 Coimbra, Portugal
Ricardo M. S. F. Almeida: Department of Civil Engineering, School of Technology and Management, Polytechnic Institute of Viseu, Campus Politécnico de Repeses, 3504-510 Viseu, Portugal
José A. R. Mendes Silva: Civil Engineering Research and Innovation for Sustainability (CERIS), Department of Civil Engineering, University of Coimbra, Rua Luís Reis Santos, Pólo II, 3030-788 Coimbra, Portugal

Energies, 2023, vol. 16, issue 13, 1-16

Abstract: This article contributes to the assessment of the hygrothermal conditions of residential buildings in the Azores archipelago and defines strategies that may contribute to the improvement in indoor air quality. These objectives were fulfilled by in situ monitoring of the hygrothermal conditions of a typical building on Terceira Island. Complementary tests to determine the thermal conductivity of exterior walls and ventilation rates were also conducted. The results were used to validate a simulation model, and different ventilation strategies were simulated using the combined heat, air, and moisture transfer model in EnergyPlus. The model took into account the typical construction methods and materials of the archipelago, as well as the reference weather data sets available for the region. The monitoring campaign showed that the percentage of time in which thermal comfort conditions were achieved was very low, varying from 5% to 32%, being the main cause for discomfort in the humidity level in the indoor environment. The simulation results pointed out the sensitivity of the problem, showing that ventilation may not always be, by itself, beneficial to thermal comfort. In particular, ventilation strategies should be established taking into account additional criteria other than the air change rate, namely the periods of the day and year in which ventilation should be performed, as well as the duration of these periods.

Keywords: buildings; EnergyPlus; hygrothermal performance; humidity ratio; numerical simulation; temperature; thermal comfort; ventilation (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/16/13/5075/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/13/5075/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:13:p:5075-:d:1184007

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:16:y:2023:i:13:p:5075-:d:1184007