EconPapers    
Economics at your fingertips  
 

Analysis of the Effect of Packing Materials (Fills) and Flow Rate on the Range and Efficiency of a Forced Draft Evaporative Cooling Tower

Swapnil S. Shinde (), Nitin P. Gulhane, Jan Taler, Paweł Ocłoń, Dawid Taler and Roberto de Lieto Vollaro
Additional contact information
Swapnil S. Shinde: Department of Mechanical Engineering, Veermata Jijabai Technological Institute (VJTI), Mumbai 400019, India
Nitin P. Gulhane: Department of Mechanical Engineering, Veermata Jijabai Technological Institute (VJTI), Mumbai 400019, India
Jan Taler: Department of Energy, Cracow University of Technology, 31-864 Cracow, Poland
Paweł Ocłoń: Department of Energy, Cracow University of Technology, 31-864 Cracow, Poland
Dawid Taler: Department of Energy, Cracow University of Technology, 31-864 Cracow, Poland
Roberto de Lieto Vollaro: Department of Industrial, Electronic and Mechanical Engineering, Roma Tre University, Via Ostiense, 133, 00154 Rome, Italy

Energies, 2023, vol. 16, issue 14, 1-15

Abstract: In the present study, experimental investigation is carried out on two different kinds of packing materials (fills). PVC fills that are traditionally used in the industry are compared and analyzed against the cellulose-based paper fills. Different mass flow rates of air are used to study the effect of the flow rate of air on the forced draft cooling tower. The volume flow rate of water also varied, and the range of the cooling tower, along with efficiency, was analyzed. Along with these two parameters, the effect of inlet water temperature on the performance of the tower was studied. Cooling tower efficiency was plotted against different L/G ratios ranging from 0.95 to 7.67. Results showed that the type of packing has a significant impact on the cooling tower performance. Paper fills gave a maximum cooling tower efficiency and range equal to 93.12% and 16.5 °C, respectively. The optimal L/G ratio range of 0.96 to 1.44 was identified as the point at which the cooling tower demonstrated its highest performance. The effect of the mass flow rate of water on the performance of the tower was far greater compared to the volume flow rate of water and inlet water temperature. The paper fills are found to be most effective under current experimental conditions, and the same can be implemented in the industrial towers under a wide spectrum of inlet water temperatures, mass flow rates of air, and volume flow rates of water.

Keywords: packing materials (fills); evaporative cooling tower; counterflow cooling tower; flow rate (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/16/14/5255/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/14/5255/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:14:p:5255-:d:1189897

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:16:y:2023:i:14:p:5255-:d:1189897