Thermohydraulic Efficiency of a Solar Air Heater in the Presence of Graded Aluminium Wire Mesh—A Combined Experimental–Numerical Study
Rawal Diganjit,
Nagaranjan Gnanasekaran () and
Moghtada Mobedi ()
Additional contact information
Rawal Diganjit: Department of Mechanical Engineering, National Institute of Technology, Surathkal, Mangalore 575025, India
Nagaranjan Gnanasekaran: Department of Mechanical Engineering, National Institute of Technology, Surathkal, Mangalore 575025, India
Moghtada Mobedi: Mechanical Engineering Department, Faculty of Engineering, Shizuoka University, 3-5-1 Johoku, Naka-ku, Hamamatsu-shi 432-8561, Japan
Energies, 2023, vol. 16, issue 15, 1-32
Abstract:
In this work, aluminium wire mesh (WM) samples with 3, 9, and 18 pores per inch (PPI) and porosities of 0.894, 0.812, and 0.917, respectively, were combined together to form graded structures including 3-9-18, 9-18-3, and 18-3-9 PPIs. A 5 mm thickness for each WM was considered for a length of 2 m and inserted into a single-pass solar air heater (SAH) in which the height of the SAH was 120 mm. For the numerical analysis, a 3D numerical model was considered in ANSYS fluent software, and the Rosseland radiation model renormalization group (RNG) k-? enhanced wall function was incorporated to account for solar radiation. The local thermal equilibrium (LTE) model was considered to obtain the heat-transfer characteristics of the WM. The numerical results of the thermohydraulic performance parameter (THPP) of the 9-18-3 PPI WM were 13.04% and 11.92% higher than the 3-9-18 and 18-3-9 PPI samples, respectively. Later, 25% of the 9-18-3 graded wire mesh (GWM) was considered at four different locations, i.e., 0, 0.5, 1, and 1.5 m away from the inlet, and analysed to obtain the best location for efficient heat transfer. The computational results show that 1.5 m away from the inlet is the best location among the different locations considered. The experimental results of the GWM at 1.5 m away from the inlet demonstrated a 20.91% and 23.32% increase in thermal efficiency compared to the empty channel for the 0.027 kg/s and 0.058 kg/s mass flow rates, respectively. From numerical-cum-experimental analysis, it was found that inserting 25% length of GWM of the entire length of the test section at a distance of 1.5 m from the inlet in single pass SAH improves the overall performance of the empty channel of single-pass SAH.
Keywords: solar air heater; graded aluminium wire mesh; local thermal equilibrium; Rosseland radiation model; thermohydraulic performance parameter; thermohydraulic efficiency (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/16/15/5633/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/15/5633/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:15:p:5633-:d:1203211
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().