EconPapers    
Economics at your fingertips  
 

Partial Discharge-Originated Deterioration of Insulating Material Investigated by Surface-Resistance and Potential Mapping

Marek Florkowski () and Maciej Kuniewski
Additional contact information
Marek Florkowski: Department of Electrical and Power Engineering, Faculty of Electrical Engineering, Automatics, Computer Science, and Biomedical Engineering, AGH University of Krakow, al. Mickiewicza 30, 30-059 Krakow, Poland
Maciej Kuniewski: Department of Electrical and Power Engineering, Faculty of Electrical Engineering, Automatics, Computer Science, and Biomedical Engineering, AGH University of Krakow, al. Mickiewicza 30, 30-059 Krakow, Poland

Energies, 2023, vol. 16, issue 16, 1-17

Abstract: The endurance of medium- and high-voltage electrical insulation is a key reliability element in a broad spectrum of applications that cover transmission and distribution levels, the transportation segment, the industrial environment, and power electronics-based energy-conversion systems. The high electric-field stress and high-frequency switching phenomena as well as the impact of environmental conditions lead to the occurrence of partial discharges (PD) and the subsequent deterioration of electrical insulation. Partial discharges usually occur inside solid insulation materials in tiny voids that may either be located adjacent to the electrodes or in the bulk of dielectric material. This effect refers to both AC and DC systems; however, AC voltage is usually much more intensive as compared to DC voltage. This paper describes a novel combined approach based on surface-resistance and potential mapping to reveal the effects of internal processes and the deterioration of insulating material due to the actions of partial discharges. To realize the research objective, the following two-step approach was proposed. Multi-point resistance mapping enables us to identify the spots of discharge channels, manifesting a-few-orders-of-magnitude-lower surface resistance as compared to untreated areas. In addition, surface-potential mapping that was stimulated by corona-charge deposition reflects quasi-equipotential clusters and the related polarity-dependent dynamics of charge decay. A high spatial and temporal resolution allows for the precise mapping and tracing of decay patterns. Experiments were carried out on polyethylene (PE) and Nomex specimens that contained embedded voids. During PD events, the effective discharge areas are identified along with the memory effects that originate from the accumulation of surface charges. Long-term aging processes may drive the formation of channels that are initiated from the deteriorated micro clusters, in turn, penetrating the bulk isolation. The presented methodology and experimental results extend the insight into PD mechanisms and internal surface processes.

Keywords: partial discharges; surface-resistance mapping; surface-potential decay; electrical insulation degradation; aging (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1996-1073/16/16/5973/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/16/5973/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:16:p:5973-:d:1216993

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:16:y:2023:i:16:p:5973-:d:1216993