Optimal Voltage Control Method for a Step Voltage Regulator Considering the Under-Load Tap Changer in a Distribution System Interconnected with a Renewable Energy Source

Hyun-ok Lee, Dae-Jin Kim, Chun-Sung Kim () and Byungki Kim ()
Additional contact information
Hyun-ok Lee: Department of Electrical Engineering, Korea Polytechnics, 85, Haseo-ro, Buk-gu 61099, Gyeonggi, Republic of Korea
Dae-Jin Kim: Electric Power System Research Team, Korea Institute of Energy Research (KIER), 200 Haemajihaean-ro, Gujwa-eup, Jeju 63357, Jeju Specific Self-Governing Province, Republic of Korea
Chun-Sung Kim: Department of Energy Innovative Industry R&D, Green Energy Institute, 370, Green-ro, Naju 58324, Jeollanam-do, Republic of Korea
Byungki Kim: Electric Power System Research Team, Korea Institute of Energy Research (KIER), 200 Haemajihaean-ro, Gujwa-eup, Jeju 63357, Jeju Specific Self-Governing Province, Republic of Korea

Energies, 2023, vol. 16, issue 16, 1-18

Abstract: The voltage in distribution systems is controlled by the under-load tap changer of the substation and the pole transformer of the primary feeders. Recently, as one of the main countermeasures, a step voltage regulator is being introduced to solve voltage problems such as overvoltage phenomena in a distribution feeder interconnected with a renewable energy source and under voltage in a long-distance feeder. However, the tap of the step voltage regulator may be frequently operated due to its interdependent relationship with the under-load tap changer in the distribution system. Furthermore, given the existing operating characteristics of the step voltage regulator, it is difficult to perfectly maintain the customer voltage within an allowable limit using existing methods such as the line drop compensation method for a step voltage regulator. In addition, the existing line drop compensation method, considering the distributed generators, may be not able to control the proper voltage within an allowable limit. Therefore, in order to solve such voltage problems, this paper proposes a voltage control method for a step voltage regulator by considering the output voltage of an under-load tap changer that is operated via the line drop compensation method. In other words, to overcome the limitations of existing voltage control methods for step voltage regulators, this paper proposes an optimal control method to determine the optimal compensation rate for a step voltage regulator by considering the reverse power flow from a renewable energy source and the output voltage of the under-load tap changer of the main transformer.

Keywords: under-load tap changer; step voltage regulator; customer voltage; line drop compensation; reverse power flow (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)

Downloads: (external link)
https://www.mdpi.com/1996-1073/16/16/6039/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/16/6039/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:16:p:6039-:d:1219515

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:16:y:2023:i:16:p:6039-:d:1219515