Performance Assessment of Solar Desiccant Air Conditioning System under Multiple Controlled Climatic Zones of Pakistan

Sibghat Ullah () and Muzaffar Ali
Additional contact information
Sibghat Ullah: Mechanical Engineering Department, University of Engineering and Technology, Taxila 47050, Pakistan
Muzaffar Ali: Mechanical Engineering Department, University of Engineering and Technology, Taxila 47050, Pakistan

Energies, 2023, vol. 16, issue 19, 1-22

Abstract: Over the past decade, the integration of desiccant technology with evaporative cooling methods has proven to be highly effective and efficient in providing comfortable indoor environments. The performance of desiccant-based direct evaporative cooling (DEC) systems is strongly influenced by environmental conditions, and their output behavior varies across multiple climatic zones. It is not easy to assess the system performance in numerous climatic zones as it is a time-consuming process. The current study focuses on determining the feasibility of a solid desiccant integrated with a direct evaporative cooler (SDI-DEC) for three different climatic zones of Pakistan: Lahore (hot and humid), Islamabad (hot and semi-humid) and Karachi (moderate and humid). To serve this purpose, a specially designed controlled climate chamber with an integrated air handling unit (AHU) was installed to create multiple environmental conditions artificially. It could also provide global climatic conditions under temperature and absolute humidity ranges of 10 °C to 50 °C and 10 g/kg to 20 g/kg, respectively. The weather conditions of the selected cities were artificially generated in the climate chamber. Based on different operating conditions, such as inlet air temperature, humidity and regeneration temperature, the performance of the system was estimated using performance indicators like COP, dehumidification effectiveness, solar fraction and supply air conditions. Results showed that the maximum temperature achieved from solar collectors was about 70 °C from collectors with an area of 9.5 m 2 . Moreover, the observations showed that when the regeneration temperature was increased from 60 °C to 80 °C, the COP of the system decreased about 41% in a moderate and humid climate, 28% in a hot and semi-humid environment and 23% in a hot and humid climate. The results revealed that an SDI-DEC system has the potential to overcome the humidity and cooling loads of the multiple climatic scenarios of Pakistan.

Keywords: desiccant; evaporative cooling; climatic zones (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/16/19/6914/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/19/6914/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:19:p:6914-:d:1251999

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:16:y:2023:i:19:p:6914-:d:1251999