Energy and Exergy Analysis of Cascade Mixed Refrigerant Joule–Thomson System with the Application of a Precooler
Ji-Hoon Yoon,
Jung-In Yoon,
Chang-Hyo Son and
Sung-Hoon Seol ()
Additional contact information
Ji-Hoon Yoon: Department of Refrigeration and Air-Conditioning Engineering, College of Engineering, Pukyong National University, Busan 48513, Republic of Korea
Jung-In Yoon: Department of Refrigeration and Air-Conditioning Engineering, College of Engineering, Pukyong National University, Busan 48513, Republic of Korea
Chang-Hyo Son: Department of Refrigeration and Air-Conditioning Engineering, College of Engineering, Pukyong National University, Busan 48513, Republic of Korea
Sung-Hoon Seol: Department of Refrigeration and Air-Conditioning Engineering, College of Engineering, Pukyong National University, Busan 48513, Republic of Korea
Energies, 2023, vol. 16, issue 19, 1-18
Abstract:
This study proposes the application of a precooler to the cascade mixed refrigerant Joule–Thomson (CMR J–T) cycle, herein referred to as the precooled CMR J–T (PCMR J–T) system. The purpose of the precooler is to utilize the temperature gradient characteristics within the two-phase region exhibited by the non-azeotropic mixed refrigerant. The precooler reduces the temperature of the high-temperature gas exiting the compressor by using cooling water from the condenser, thereby decreasing the capacity requirements of the high-temperature cycle (HTC). The working fluid comprises a nonflammable mixed refrigerant (R218, R23, R14, and Ar), and simulations were conducted by varying the HTC evaporation temperature and cooling water temperature for energy and exergy analysis. Under the analysis conditions, the capacity of each component in the HTC can be reduced by over 45%, leading to a maximum increase of 21.6% in the system’s coefficient of performance. Furthermore, the exergy destruction in the PCMR J–T system decreases along with the reduction in component capacity, with the most significant reduction occurring at the HTC expansion valve. The exergy efficiency of the system increases by up to 47.4%.
Keywords: mixed refrigerant; Joule–Thomson; nonflammable refrigerant; precooler; energy and exergy analysis (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/16/19/6991/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/19/6991/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:19:p:6991-:d:1255293
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().