One-Step Ahead Control Using Online Interpolated Transfer Function for Supplementary Control of Air-Fuel Ratio in Thermal Power Plants
Hyuk Choi,
Ju-Hong Lee,
Ji-Hoon Yu,
Un-Chul Moon (),
Mi-Jong Kim and
Kwang Y. Lee
Additional contact information
Hyuk Choi: School of Electrical and Electronics Engineering, Chung-Ang University, Seoul 06974, Republic of Korea
Ju-Hong Lee: School of Electrical and Electronics Engineering, Chung-Ang University, Seoul 06974, Republic of Korea
Ji-Hoon Yu: School of Electrical and Electronics Engineering, Chung-Ang University, Seoul 06974, Republic of Korea
Un-Chul Moon: School of Electrical and Electronics Engineering, Chung-Ang University, Seoul 06974, Republic of Korea
Mi-Jong Kim: Kepco Kps Overseas Maintenance Service Center, 211 Munhwa-ro, Naju-si 58326, Jeollanam-do, Republic of Korea
Kwang Y. Lee: Department of Electrical and Computer Engineering, Baylor University, Waco, TX 76798-7356, USA
Energies, 2023, vol. 16, issue 21, 1-18
Abstract:
Recently, the environmental problem has become a global issue. The air to fuel ratio (AFR) in the combustion of thermal power plants directly influences pollutants and thermal efficiency. A research result was published showing that the AFR control performance of thermal power plants can be improved through supplementary control using dynamic matrix control (DMC). However, online optimization of DMC needs an extra computer server in implementation. This paper proposes a practical AFR control with one-step ahead control which does not use online optimization and can be implemented directly in existing distributed control system (DCS) of thermal power plants. Closed-loop transfer function models at three operating points are independently developed offline. Then, an online transfer function using interpolation of offline models is applied at each sampling step. A simple one-step ahead control with online transfer function is applied as a supplementary control of AFR. Simulations with two different type power plants, a 600 MW oil-fired drum-type power plant and a 1000 MW ultra supercritical (USC) coal-fired once-through type power plant, are performed to show the effectiveness of the proposed control structure. Simulation results show that the proposed supplementary control can effectively improve the conventional AFR control performance of power plants.
Keywords: air to fuel ratio; combustion control; one-step ahead control; power plant control (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/16/21/7411/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/21/7411/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:21:p:7411-:d:1273251
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().