Radiators Adjustment in Multi-Family Residential Buildings—An Analysis Based on Data from Heat Meters

Karol Bandurski (), Andrzej Górka and Halina Koczyk
Additional contact information
Karol Bandurski: Faculty of Environmental Engineering and Energy, Institute of Environmental Engineering and Building Installations, Poznań University of Technology, Berdychowo 4, 60-965 Poznań, Poland
Andrzej Górka: Faculty of Environmental Engineering and Energy, Institute of Environmental Engineering and Building Installations, Poznań University of Technology, Berdychowo 4, 60-965 Poznań, Poland
Halina Koczyk: Faculty of Environmental Engineering and Energy, Institute of Environmental Engineering and Building Installations, Poznań University of Technology, Berdychowo 4, 60-965 Poznań, Poland

Energies, 2023, vol. 16, issue 22, 1-22

Abstract: Energy is consumed in buildings through the use of various types of energy systems, which are controlled by the occupants via provided interfaces. The quality of this control should be verified to improve the efficiency of the systems and for the comfort of the occupants. In the case of residential buildings, due to privacy reasons, it is problematic to directly monitor human–building interactions using sensors installed in dwellings. However, data from increasingly common smart meters are easily available. In this paper, the potential use of data from heat meters is explored for the analysis of occupant interactions with space-heating (SH) systems. A pilot study is conducted based on a one-year set of daily data from 101 dwellings. First, the identification of an indoor temperature and a strategy for thermostatic radiator valve (TRV) adjustments for all the investigated dwellings is presented. Second, the performed analysis suggests that 96% of the households did not use the automatic adjustment function of the TRVs since adjustments using the on–off mode were the most common, which could be empirical evidence for Kempton’s theory on mental models of home heating controls. The reasons for this could be the weakness of the TRV as an SH interface and the technical specificity of the analyzed SH (its supply temperature). The preliminary investigation confirms the potential of the proposed methodology, but further research is needed.

Keywords: heating; smart meters; TRV; occupant behavior; residential building thermostats (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/16/22/7485/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/22/7485/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:22:p:7485-:d:1276035

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:16:y:2023:i:22:p:7485-:d:1276035