Analysis of Reactive Power in Electrical Networks Supplying Nonlinear Fast-Varying Loads
Yuriy Sayenko (),
Ryszard Pawelek and
Tetiana Baranenko
Additional contact information
Yuriy Sayenko: Institute of Electrical Power Engineering, Lodz University of Technology, 20 Stefanowskiego Street, 90-537 Lodz, Poland
Ryszard Pawelek: Institute of Electrical Power Engineering, Lodz University of Technology, 20 Stefanowskiego Street, 90-537 Lodz, Poland
Tetiana Baranenko: Department of Automation Electrical Systems and Electric Drive, Pryazovskyi State Technical University, 7 Universytetska Street, 87555 Mariupol, Ukraine
Energies, 2023, vol. 16, issue 24, 1-13
Abstract:
This study concerns problems related to the assessment of reactive power in power networks with nonlinear fast-varying loads, such as electric arc furnaces, rolling mill drives, etc. The operation of this type of load is characterized by the introduction of interharmonic currents (including higher harmonics) into the power supply network and a relatively low power factor. Rapid changes in the RMS value of the current also cause voltage fluctuations and the related phenomenon of light-flickering. Therefore, there is a need to evaluate the power selection of compensating devices, taking into account the random nature of load changes and the distortion of current and voltage waveforms, in particular, interharmonic components, the impact of which has not been fully investigated so far. To analyze the random nature of load changes, autocorrelation functions were used, which allowed for the estimation of the expected values of the arc furnace current distortion coefficient (based on the recorded waveforms). In order to determine the parameters of reactive power compensating devices, and in particular capacitor banks, an autocorrelation function in the exponential-cosine-sine form was used, which meets the conditions of differentiation. This study contains comparative results of the reactive power of capacitor banks determined using different methods. The criterion for selecting capacitor bank parameters was the minimization of energy losses in the power supply network. The calculations presented in this study show that by taking into account higher harmonics and interharmonics in the voltage and currents of fast-varying loads, the installed power of the capacitor bank can be reduced by approximately 7%, and energy losses in the power grid can be reduced by 3–5%.
Keywords: reactive power; higher harmonics; interharmonics; random processes; autocorrelation function (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/16/24/8011/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/24/8011/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:24:p:8011-:d:1298062
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().